# Welding hot work permit example

> MIG welding during a refurbishment, with fume extraction and the office above checked too. A filled permit to read here or download as PDF, Word or Excel.
> Web page: https://complyonsite.com/tools/permit-to-work-examples?job=hot-work-welding

[All 7 examples](https://complyonsite.com/tools/permit-to-work-examples?job=hot-work-welding#ex-choose)

## Welding a steel beam in a basement

MIG welding during a refurbishment, with fume extraction and the office above checked too.

[Download PDF](https://complyonsite.com/permit/examples/hot-work-welding.pdf) [Download Word](https://complyonsite.com/permit/examples/hot-work-welding.docx)

[Download Excel](https://complyonsite.com/permit/examples/hot-work-welding.xlsx)

### Sources

- [HSG168: Fire safety in construction](https://www.hse.gov.uk/pubns/priced/hsg168.pdf)
- [HSE bulletin STSU1 2019: mild steel welding fume](https://www.hse.gov.uk/safetybulletins/mild-steel-welding-fume.htm)

Worked example of a made-up job. Not a permit.

### Sheet 1: Hot Work Permit

#### Hollins & Reed Contracting Ltd

1. **Permit no.** HR-0418
2. **Site** Unit 3, Canal Side Business Park
3. **Exact location** Basement, beam at grid line C4

#### Details

1. **Contractor** Hollins & Reed
2. **Issued to** Priya Shah
3. **Valid from** 13/10/26 08:00
4. **Valid to** 13/10/26 17:00
5. **RAMS ref** HR-RAMS-08
6. **Fire risk ref** HR-FRA-03

#### The work

1. **Hot work to be done** Weld two stiffener plates to the existing steel beam, to the engineer’s drawing S-04.
2. **Method** Old bracket ground off. MIG welding with argon-mix gas. One welder, one fire watcher.
3. **Why cold methods fail** The drawing calls for welded plates. Bolts need holes the flange cannot take.

#### Hazards

1. **Combustibles in 10 m** Yes
2. **Openings and voids** Yes
3. **Flammables nearby** No
4. **Dust or lint** No
5. **Roof or wall linings** No
6. **Below, behind walls** Yes
7. **Sprinklers, alarms** Yes
8. **Occupied building** Yes

#### Precautions

1. **Combustibles removed or covered** Done: yes. By: Reece Ollerton
2. **Floors swept, combustible floors covered** Done: yes. By: Reece Ollerton
3. **Openings and voids sealed** Done: yes. By: Reece Ollerton
4. **Non-combustible screens up** Done: yes. By: Reece Ollerton
5. **Detectors isolated: who restores them** Done: yes. By: Dan Hollins, zone 1 only
6. **Gas cylinders secured and checked** Done: yes. By: Priya Shah
7. **Two extinguishers within reach: type** Done: yes. By: CO2 and dry powder
8. **Fire watcher named, breaks covered** Done: yes. By: Reece Ollerton
9. **How to raise the alarm** Done: yes. By: Break glass, ring 999
10. **Hot work ends 2 hours before day end** Done: yes
11. **Others shielded from arc and sparks** Done: yes. By: Priya Shah, screens
12. **Fume: LEV or RPE** Done: yes. By: LEV and RPE, both
13. **Permit shown at the work** Done: yes

#### Equipment

1. **Extinguishers** Yes
2. **Fire blanket** Yes
3. **Hose reel** No
4. **Gas detector** No
5. **Thermal camera** Yes
6. **Welding screens** Yes

#### Other conditions

1. **No flammable gas below ground. Extraction at the weld, ducted outside. Welder wears RPE as well.**
2. **Riser boarded. Watcher checks the office above and behind the riser wall. Site office 0161 496 0142.**

#### Sign-off

1. **Issued: precautions checked** Name: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 07:50
2. **Accepted: permit understood** Name: Priya Shah. Signature: signed. Date: 13/10/26. Time: 07:55

### Sheet 2: Hot Work Permit

#### Hollins & Reed Contracting Ltd

1. **Permit no.** HR-0418
2. **Site** Unit 3, Canal Side Business Park
3. **Exact location** Basement, beam at grid line C4

#### Fire watch: continuous for 1 hour, then a check at 2 hours

1. **During breaks** Time: 12:00 to 12:30. By: Reece Ollerton. Result: Stopped for the break. Watched basement and riser. Nothing found.
2. **End of hot work** Time: 14:30. By: Reece Ollerton. Result: Welding finished. Continuous watch started.
3. **1 hour after the end** Time: 15:30. By: Reece Ollerton. Result: Watch kept the whole hour. Office above and riser checked.
4. **2 hours after the end** Time: 16:30. By: Dan Hollins. Result: Basement, riser and office above checked. Nothing found.

#### Cancellation

1. **Work stopped at** 14:30 on 13 October. Plates welded.
2. **Area checked, images kept** Walked at 16:30. Two thermal images of the riser in the job file.
3. **Detectors restored by** Dan Hollins. Back on 12:00, off again 12:30, back on 14:35. Panel normal.
4. **Equipment removed** Welder, cylinder and screens out by 15:00. Riser boards stay.

#### Handback

1. **Area returned to** Dan Hollins, for the next trade
2. **Notes** Welds to be inspected by the engineer. Not part of this permit.

#### Sign-off

1. **Extended: new end time** Name: Not extended
2. **Work finished: people and tools clear** Name: Priya Shah. Signature: signed. Date: 13/10/26. Time: 16:32
3. **Cancelled: area checked** Name: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 16:35
4. **Handed back: area returned** Name: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 16:40

## Choose a permit

- [**Torch-on felt on a flat roof** A propane torch on the roof of an occupied office, with a fire watch to the two-hour check.](https://complyonsite.com/tools/permit-to-work-examples?job=hot-work-roofing#example)
- [**Welding a steel beam in a basement** MIG welding during a refurbishment, with fume extraction and the office above checked too.](https://complyonsite.com/tools/permit-to-work-examples?job=hot-work-welding#example)
- [**A new drain in a yard, near live services** Hand digging near a cable and a gas pipe, over two days, with inspections after rain.](https://complyonsite.com/tools/permit-to-work-examples?job=permit-to-dig#example)
- [**Entering a foul manhole to join a drain** Two people in a 2.4 m manhole, with gas tests, a top person and a winch at the surface.](https://complyonsite.com/tools/permit-to-work-examples?job=confined-space#example)
- [**A night fit-out in a bank branch** A shopfitting team replacing a reception desk and two partitions after closing, with one intruder alarm zone off and security on site.](https://complyonsite.com/tools/permit-to-work-examples?job=general#example)
- [**A roof survey behind a barrier** A surveyor and an assistant on a large flat felt roof with roof lights and an open edge, inside a barrier set and struck on the same permit, with wind readings throughout.](https://complyonsite.com/tools/permit-to-work-examples?job=working-at-height#example)
- [**Changing a sub-main board** A board with two incomers and a generator inlet, with both firms locked on through a lock-out box, proved dead before the permit was issued.](https://complyonsite.com/tools/permit-to-work-examples?job=electrical-isolation#example)

## What a completed permit shows

- Who issued it and who accepted
- What was checked first, and what did not apply
- The record while it ran (fire watch, gas tests, inspections)
- How it was cancelled and handed back