Welding hot work permit example
All 7 examplesWelding a steel beam in a basement
MIG welding during a refurbishment, with fume extraction and the office above checked too.
Sources
Worked example of a made-up job. Not a permit.
Sheet 1: Hot Work Permit
Hollins & Reed Contracting Ltd
- Permit no.HR-0418
- SiteUnit 3, Canal Side Business Park
- Exact locationBasement, beam at grid line C4
Details
- ContractorHollins & Reed
- Issued toPriya Shah
- Valid from13/10/26 08:00
- Valid to13/10/26 17:00
- RAMS refHR-RAMS-08
- Fire risk refHR-FRA-03
The work
- Hot work to be doneWeld two stiffener plates to the existing steel beam, to the engineer’s drawing S-04.
- MethodOld bracket ground off. MIG welding with argon-mix gas. One welder, one fire watcher.
- Why cold methods failThe drawing calls for welded plates. Bolts need holes the flange cannot take.
Hazards
- Combustibles in 10 mYes
- Openings and voidsYes
- Flammables nearbyNo
- Dust or lintNo
- Roof or wall liningsNo
- Below, behind wallsYes
- Sprinklers, alarmsYes
- Occupied buildingYes
Precautions
- Combustibles removed or coveredDone: yes. By: Reece Ollerton
- Floors swept, combustible floors coveredDone: yes. By: Reece Ollerton
- Openings and voids sealedDone: yes. By: Reece Ollerton
- Non-combustible screens upDone: yes. By: Reece Ollerton
- Detectors isolated: who restores themDone: yes. By: Dan Hollins, zone 1 only
- Gas cylinders secured and checkedDone: yes. By: Priya Shah
- Two extinguishers within reach: typeDone: yes. By: CO2 and dry powder
- Fire watcher named, breaks coveredDone: yes. By: Reece Ollerton
- How to raise the alarmDone: yes. By: Break glass, ring 999
- Hot work ends 2 hours before day endDone: yes
- Others shielded from arc and sparksDone: yes. By: Priya Shah, screens
- Fume: LEV or RPEDone: yes. By: LEV and RPE, both
- Permit shown at the workDone: yes
Equipment
- ExtinguishersYes
- Fire blanketYes
- Hose reelNo
- Gas detectorNo
- Thermal cameraYes
- Welding screensYes
Other conditions
- No flammable gas below ground. Extraction at the weld, ducted outside. Welder wears RPE as well.
- Riser boarded. Watcher checks the office above and behind the riser wall. Site office 0161 496 0142.
Sign-off
- Issued: precautions checkedName: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 07:50
- Accepted: permit understoodName: Priya Shah. Signature: signed. Date: 13/10/26. Time: 07:55
Sheet 2: Hot Work Permit
Hollins & Reed Contracting Ltd
- Permit no.HR-0418
- SiteUnit 3, Canal Side Business Park
- Exact locationBasement, beam at grid line C4
Fire watch: continuous for 1 hour, then a check at 2 hours
- During breaksTime: 12:00 to 12:30. By: Reece Ollerton. Result: Stopped for the break. Watched basement and riser. Nothing found.
- End of hot workTime: 14:30. By: Reece Ollerton. Result: Welding finished. Continuous watch started.
- 1 hour after the endTime: 15:30. By: Reece Ollerton. Result: Watch kept the whole hour. Office above and riser checked.
- 2 hours after the endTime: 16:30. By: Dan Hollins. Result: Basement, riser and office above checked. Nothing found.
Cancellation
- Work stopped at14:30 on 13 October. Plates welded.
- Area checked, images keptWalked at 16:30. Two thermal images of the riser in the job file.
- Detectors restored byDan Hollins. Back on 12:00, off again 12:30, back on 14:35. Panel normal.
- Equipment removedWelder, cylinder and screens out by 15:00. Riser boards stay.
Handback
- Area returned toDan Hollins, for the next trade
- NotesWelds to be inspected by the engineer. Not part of this permit.
Sign-off
- Extended: new end timeName: Not extended
- Work finished: people and tools clearName: Priya Shah. Signature: signed. Date: 13/10/26. Time: 16:32
- Cancelled: area checkedName: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 16:35
- Handed back: area returnedName: Dan Hollins. Signature: signed. Date: 13/10/26. Time: 16:40
Choose a permit
- Torch-on felt on a flat roof A propane torch on the roof of an occupied office, with a fire watch to the two-hour check.
- Welding a steel beam in a basement MIG welding during a refurbishment, with fume extraction and the office above checked too.
- A new drain in a yard, near live services Hand digging near a cable and a gas pipe, over two days, with inspections after rain.
- Entering a foul manhole to join a drain Two people in a 2.4 m manhole, with gas tests, a top person and a winch at the surface.
- A night fit-out in a bank branch A shopfitting team replacing a reception desk and two partitions after closing, with one intruder alarm zone off and security on site.
- A roof survey behind a barrier A surveyor and an assistant on a large flat felt roof with roof lights and an open edge, inside a barrier set and struck on the same permit, with wind readings throughout.
- Changing a sub-main board A board with two incomers and a generator inlet, with both firms locked on through a lock-out box, proved dead before the permit was issued.
What a completed permit shows
- Who issued it and who accepted
- What was checked first, and what did not apply
- The record while it ran (fire watch, gas tests, inspections)
- How it was cancelled and handed back