Choose a design PUWER work equipment PUWER Inspection Checklist Equipment Serial or plant… Location Inspector Date Frequency Guarding and controls Pass Fail N/A Finding Guards fitted, secure and not defeated Controls present, visible and identifiable Control systems respond correctly Limit switches, overloads, interlocks work Stop and emergency stop Pass Fail N/A Finding Normal stop works and is easy to reach Emergency stop works and is easy to reach Isolation from energy Pass Fail N/A Finding Isolators present and identifiable, all e… Stability and lighting Pass Fail N/A Finding Clamped or stabilised where needed Lighting suitable at the point of use Markings and warnings Pass Fail N/A Finding Health and safety markings clear Warnings and warning devices work Maintenance and condition Pass Fail N/A Finding Evidence of last inspection present Condition: wear, damage, deterioration Maintenance up to date, log current if ke… Maker’s routine items, such as fluid leve… Operator competence and information Pass Fail N/A Finding Users trained, instructions available For this equipment Pass Fail N/A Finding Result Pass Fail Tag no. Reported to Put right on Overall result Inspected by Signed Date Next inspection due UNCONTROLLED COPY IF PRINTED Ladder, detailed Ladder Detailed Visual Inspection Ladder ID Type Standard on label Location Inspector Date All ladders OK Defect N/A What was found Feet: not damaged or worn Stiles: not twisted, bent or dented Rungs: not cracked, worn, bent or loose Tie rods: present and undamaged Welded joints: no cracks or damage Rivets tight, stays undamaged Stability devices and accessories, per the… Stepladders OK Defect N/A What was found Locking mechanism works, not bent or worn Platform not split or buckled Steps or treads: not loose, worn or slippery Extension ladders OK Defect N/A What was found Sections held from moving against each other Rope and pulley, if fitted: not worn or fra… Labels and storage OK Defect N/A What was found Label readable, inspection status shown Standard on label: EN 131, or older BS 2037… Maintained and stored per the maker Outcome In use Taken out of use Action Tag number Reported to After this inspection Inspected by Signed Date Next inspection due UNCONTROLLED COPY IF PRINTED The user’s pre-use check each working day is separate, and HSE does not ask for it to be recorded. Ladder, pre-use Ladder Pre-use Check Ladder ID Type Location Date Every ladder OK Defect N/A What was found Stiles: not bent or damaged Feet: none missing, worn or damaged Feet clean: no soil, stones or chippings on… Rungs: none bent, worn, missing or loose Rungs and treads free of mud, oil or paint Locks work, fixings sound, locking bars eng… Stability devices and accessories, per the… Stepladders OK Defect N/A What was found Platform: not split or buckled Steps or treads: clean, fixings tight Outcome In use Not used Who was told After this check Checked by Signed UNCONTROLLED COPY IF PRINTED Check at the start of the working day and again after a drop, or a move from dirty ground to a clean, hard surface. Harness and lanyard, detailed Harness and Lanyard Inspection Harness ID Lanyard ID Make and model Location Made on In service… Inspector Date Inspection Detailed, six-monthly Detailed, three-monthly Interim This inspection Identity OK Defect N/A What was found Unique ID, indelibly marked Last detailed inspection within its interval Has never arrested a fall Harness and lanyard labels readable, in pro… Webbing and stitching OK Defect N/A What was found Edges: no cuts of 1 mm or more No abrasion on the face, loops or edges Fibres not softened or hardened No chemical attack, flaking or colour change No heat or friction damage, glazed fibres No UV damage: colour loss, powdery surface Free of dirt, grit, sand and paint Stitching not cut or abraded Lanyard and energy absorber OK Defect N/A What was found No knot the maker did not intend Energy absorber not part deployed Protective sleeve in place, undamaged Stitching and sewn ends: none loose or pull… Hardware and connectors OK Defect N/A What was found D-rings, buckles, keepers: no cracks, burrs… Buckles and adjusters fasten and hold Karabiners, screwlinks, scaffold hooks sound Connector gates close and lock by themselves Rope, if fitted OK Defect N/A What was found Kernmantel: sheath and core sound, no rucki… Cable-laid rope: no internal damage Outcome In use Withdrawn Action After this inspection Inspected by Signed Date Next detailed inspection due UNCONTROLLED COPY IF PRINTED Before each use, the user runs the harness and lanyard slowly through the hands, in good light. Harness and lanyard, pre-use Harness and Lanyard Pre-use Check Harness ID Lanyard ID Location Date Label OK Defect N/A What was found Label on and readable, within product life CE or UKCA marked Detailed inspection within its interval Harness OK Defect N/A What was found Webbing: no cuts, fraying, burns or chemica… Stitching: none loose, pulled or cut D-rings, buckles, keepers: no damage or cor… Buckles fastened and adjusted, and they hold Lanyard and connectors OK Defect N/A What was found Stitching and sewn ends: none loose or pull… Webbing or rope: no cuts, even 1 mm at an e… No abrasion, burns, stiffness or chemical m… Energy absorber not part deployed No knot the maker did not intend Hooks and karabiners: gates close and lock Fall indicator, if fitted, not showing Outcome In use Not used Who was told After this check Checked by Signed UNCONTROLLED COPY IF PRINTED Run it all slowly through your hands, in good light. Maker’s instructions first; for wire or retractable lanyards, onl… LOLER lifting equipment LOLER Pre-use Check and Inspection Equipment ID SWL Location Inspector Date Thorough examination Last thorough examination Report of thorough examination reference All equipment Pass Fail N/A Finding ID and SWL marked and readable Last thorough examination in date, report… People-lifting equipment marked as such Chain slings Pass Fail N/A Finding Top fitting not distorted Chain not stretched, links move freely Links not bent or twisted No wear at interlink seats Hook throat not opened out, lower fitting… Safety catch works No cuts, nicks, gouges, cracks or corrosi… No heat discolouration Joining devices correctly assembled Wire rope slings Pass Fail N/A Finding Terminal fittings and thimbles sound Rope, splice, ferrule sound, not slipping No broken wires Safety catches work No corrosion or dried lubricant No kinks or permanent set Wires and strands in place, core not show… No heat damage, blueing, spatter or arcing Hook throat not opened out, fittings sound Shackles and hooks Pass Fail N/A Finding Shackles not distorted Hooks have a safety catch where possible Page 1 of 2 UNCONTROLLED COPY IF PRINTED This check does not replace the thorough examination. Forklift pre-shift Forklift Pre-shift Check · Weekly Truck ID Week commencing Walk round, truck off Shift 1 Shift 2 Shift 3 Shift 4 Shift 5 Shift 6 Shift 7 Tyres: damage, swarf, nails, cuts, bubbles Tyre pressures, if pneumatic Wheels: condition, rim flanges Wheel nuts tight and secure Forks: cracks, bent tips, positioning locks Chains: pins, bolts, links, lubrication Hydraulics: leaks, fluid level Fuel, water, engine and transmission oils Battery: charged, no leaks, lead stored Overhead guard and load back-rest Mirrors and visibility aids In the seat Shift 1 Shift 2 Shift 3 Shift 4 Shift 5 Shift 6 Shift 7 Restraint or seat belt present and working Capacity plate readable Running Shift 1 Shift 2 Shift 3 Shift 4 Shift 5 Shift 6 Shift 7 Parking brake Service brakes Steering Lift, tilt and attachments Horn or audible warning Lights Warning lights Each shift Shift 1 Shift 2 Shift 3 Shift 4 Shift 5 Shift 6 Shift 7 Date and shift Hours Operator initials Defects Shift Reported to Do not use UNCONTROLLED COPY IF PRINTED Follow the vehicle handbook first. Fire door Fire Door Check Building Address Floor Door Flat, communal, plant or ri… Checked by Date The door OK Defect Not fitted Finding Still a fire door, not a non-fire-resisting door (flat) Letterbox closed, not jammed (flat) Door, frame and securing wall: no damage, defect or alterat… Glass and glazing, including side and over panels Hinges and ironmongery Air transfer grilles (plant and riser) Strips and seals: undamaged, in contact, not painted over Gaps: no more than 4mm, except the bottom Self-closer closes fully from fully open and from about 15… Hold-open device released by its test button Door selector on double doors Plant or riser door self-closing or kept locked shut Door not wedged open Issue Proposed action By when Who Checked by Signed Date Page 1 of 2 UNCONTROLLED COPY IF PRINTED their staff, you do them on their behalf; the sheet does not change who holds the duty. The duty to check is the responsible person’s. If you do the checks for them, under a maintenance contract or as A visual check by eye, not an examination of fire resistance. OK means nothing obvious was wrong. Construction site Site Inspection Checklist Site Area Inspector Date Weather Access and egress OK Action Finding Who By when Closed Everyone can reach their work safely Routes clear and signposted Holes covered, fixed and marked Lighting adequate Housekeeping OK Action Finding Who By when Closed Site tidy, materials stored safely Walkways, stairs free of trip hazards Flammable waste removed regularly Working at height OK Action Finding Who By when Closed Scaffold: report seen, in date Double guard rails, toe boards at edges Platforms fully boarded, not overloaded Incomplete scaffold barred off Tower wheels locked, outriggers out Ladders sound, secured, about 5 rungs up Roof edges, fragile areas, area below MEWP: competent operator, SWL, inspected Excavations OK Action Finding Who By when Closed Excavation: report seen, in date Supported or battered, by a safe method Safe ladder access Barriers, stop blocks for tippers Spoil and plant kept from the edge Nearby structures, services considered Plant and vehicles OK Action Finding Who By when Closed Vehicles and pedestrians kept apart Reversing avoided or signallers used Plant maintained: steering, lights, brakes Drivers competent Loads secure, passengers only as designed Not used on dangerous slopes Unintended movement prevented Cranes, hoists: reports seen, in date Page 1 of 2 UNCONTROLLED COPY IF PRINTED Not a statutory inspection of scaffold, excavation or MEWP. Vehicle walk-round Vehicle Walk-round Check · Weekly Vehicle registration Week commencing Inside Mon Tue Wed Thu Fri Sat Sun Mirrors, cameras and glass Washers and wipers Dashboard warning lights Steering: moves, no excess play Horn Brakes: footwell clear, foot and parking Seats and seat belts Outside Mon Tue Wed Thu Fri Sat Sun Lights and indicators Fluids, fuel and oil: levels, cap, leaks Battery: secure, sound, not leaking Bodywork and doors Tyres, wheels: tread, pressure, security Load secure, doors locked AdBlue Exhaust: leaks, smoke, noise Alternative fuel systems and isolation Number plate Tow bars and trailers Other equipment, such as a tail lift Each day Mon Tue Wed Thu Fri Sat Sun Driver’s name Nil defects Mileage Date Defects Assessment Name Reported to Fixed on UNCONTROLLED COPY IF PRINTED Not a safety inspection or a service.