Permit to work examples
All 7 examplesRoofing hot work permit example
A propane torch on the roof of an occupied office, with a fire watch to the two-hour check.
Sources
Worked example of a made-up job. Not a permit.
Sheet 1: Hot Work Permit
Hollins & Reed Contracting Ltd
- Permit no.HR-0417
- SiteUnit 3, Canal Side Business Park
- Exact locationFlat roof over the offices, north end
Details
- ContractorHollins & Reed
- Issued toPriya Shah
- Valid from12/10/26 08:00
- Valid to12/10/26 17:00
- RAMS refHR-RAMS-07
- Fire risk refHR-FRA-03
The work
- Hot work to be doneTorch-on felt cap sheet to 30 m² of flat roof, with parapet upstands and two outlets.
- MethodOne torch, one cylinder. Laps rolled. Upstands on low flame, gaps behind sealed first.
- Why cold methods failCold-applied sheet and a heat gun failed a test patch on 9 October. Neither bonded.
Hazards
- Combustibles in 10 mYes
- Openings and voidsYes
- Flammables nearbyYes
- Dust or lintNo
- Roof or wall liningsYes
- Below, behind wallsYes
- Sprinklers, alarmsYes
- Occupied buildingYes
Precautions
- Combustibles removed or coveredDone: yes. By: Priya Shah
- Floors swept, combustible floors coveredDone: yes. By: Priya Shah
- Openings and voids sealedDone: yes. By: Priya Shah
- Non-combustible screens upDone: no. By: Not needed. Open roof
- Detectors isolated: who restores themDone: yes. By: Dan Hollins, zone 3 only
- Gas cylinders secured and checkedDone: yes. By: Priya Shah
- Two extinguishers within reach: typeDone: yes. By: Two 9 kg dry powder
- Fire watcher named, breaks coveredDone: yes. By: Reece Ollerton
- How to raise the alarmDone: yes. By: Break glass, ring 999
- Hot work ends 2 hours before day endDone: yes
- Others shielded from arc and sparksDone: no. By: Not needed. No arc
- Fume: LEV or RPEDone: no. By: Not needed. Outdoors
- Permit shown at the workDone: yes
Equipment
- ExtinguishersYes
- Fire blanketYes
- Hose reelNo
- Gas detectorNo
- Thermal cameraYes
- Welding screensNo
Other conditions
- Cylinder on a heat-insulating base, 3 m from the torch. Never use water on a bitumen fire.
- Zone 3 goes back on for any break and when hot work ends. Client told first. Site office 0161 496 0142.
Sign-off
- Issued: precautions checkedName: Dan Hollins. Signature: signed. Date: 12/10/26. Time: 07:50
- Accepted: permit understoodName: Priya Shah. Signature: signed. Date: 12/10/26. Time: 07:55
Sheet 2: Hot Work Permit
Hollins & Reed Contracting Ltd
- Permit no.HR-0417
- SiteUnit 3, Canal Side Business Park
- Exact locationFlat roof over the offices, north end
Fire watch: continuous for 1 hour, then a check at 2 hours
- During breaksTime: 12:15 to 12:45. By: Reece Ollerton. Result: Torch off for the break. Watched roof and void. Nothing found.
- End of hot workTime: 14:45. By: Reece Ollerton. Result: Torch off, cylinder shut. Continuous watch started.
- 1 hour after the endTime: 15:45. By: Reece Ollerton. Result: Watched roof and void the whole hour. Thermal image shows no hot spots.
- 2 hours after the endTime: 16:45. By: Dan Hollins. Result: Roof and roof void checked. Nothing found.
Cancellation
- Work stopped at14:45 on 12 October. Cap sheet finished.
- Area checked, images keptRoof and roof void walked at 16:45. Three thermal images in the job file.
- Detectors restored byDan Hollins. Back on 12:15, off again 12:45, back on 14:50. Panel normal.
- Equipment removedTorch, hose and cylinder off the roof by 15:20.
Handback
- Area returned toThornley Vale Estates Ltd, site keyholder
- NotesOutlets open again. Nothing to report.
Sign-off
- Extended: new end timeName: Not extended
- Work finished: people and tools clearName: Priya Shah. Signature: signed. Date: 12/10/26. Time: 16:47
- Cancelled: area checkedName: Dan Hollins. Signature: signed. Date: 12/10/26. Time: 16:50
- Handed back: area returnedName: Dan Hollins. Signature: signed. Date: 12/10/26. Time: 16:55
Choose a permit
- Torch-on felt on a flat roof A propane torch on the roof of an occupied office, with a fire watch to the two-hour check.
- Welding a steel beam in a basement MIG welding during a refurbishment, with fume extraction and the office above checked too.
- A new drain in a yard, near live services Hand digging near a cable and a gas pipe, over two days, with inspections after rain.
- Entering a foul manhole to join a drain Two people in a 2.4 m manhole, with gas tests, a top person and a winch at the surface.
- A night fit-out in a bank branch A shopfitting team replacing a reception desk and two partitions after closing, with one intruder alarm zone off and security on site.
- A roof survey behind a barrier A surveyor and an assistant on a large flat felt roof with roof lights and an open edge, inside a barrier set and struck on the same permit, with wind readings throughout.
- Changing a sub-main board A board with two incomers and a generator inlet, with both firms locked on through a lock-out box, proved dead before the permit was issued.
What a completed permit shows
- Who issued it and who accepted
- What was checked first, and what did not apply
- The record while it ran (fire watch, gas tests, inspections)
- How it was cancelled and handed back