Skip to content

Canadian waste code finder

B1110 Basel waste code Scrap circuit boards & electronic parts, clear of batteries & PCBs.

  • Free, no account
  • Based on ECCC's classification guide and SOR/2021-25
  • Nothing is stored

Find a Canadian waste code

B1110, Qualifying electrical and electronic assemblies.

  • Basel List B codes

    Qualifying electrical and electronic assemblies

Use B1110 for qualifying electrical and electronic assemblies as a Basel List B waste without an Annex III hazard.

Basel List B code for electrical and electronic scrap free of batteries, mercury switches, CRT glass & PCB capacitors, or for reuse.

Is Basel B1110 hazardous waste?

Not from the code alone. Basel B1110 is on Basel List B, so matching material is normally not hazardous under the Convention. It becomes hazardous if Annex I constituents give it an Annex III hazardous characteristic. SOR/2021-25 and its exclusions decide Canadian federal control.

On a federally regulated international shipment, the applicant enters the waste classification in the waste-line details of the federal notification in CNMTS. The movement rules and exclusions say when that applies.

What does Basel B1110 cover?

Covers electronic assemblies made only of metals or alloys. It also covers electrical and electronic scrap, circuit boards included but power-generation scrap excluded, when List A batteries, mercury switches, cathode-ray-tube or activated glass and PCB capacitors are absent or removed, and Annex I contamination is too low to give an Annex III characteristic. Compare A1180.

Official wording
Read the official entry

Is electrical and electronic assemblies always Basel B1110?

CodeWhen it fits
B1110Metal-only assemblies, qualifying low-hazard scrap, or material sent directly for reuse in repair or upgrading, not for recycling or disposal.

List B is a condition, not an exemption. If the material has an Annex III hazardous characteristic, or meets another Canadian or foreign hazardous-waste definition, classify it by its actual hazard and follow the rules that control the movement.

Detailed conditions for Basel B1110

Assemblies, circuit boards, components and wires sent directly for reuse also qualify, if they are meant for repair, refurbishment or upgrading without substantial rebuilding. They must not be headed for recycling or final disposal. Some countries don't treat direct-reuse material as waste.

Which codes sit beside Basel B1110?

CodeWhat it is
B1070Dispersible copper or copper-alloy waste
B1080Non-hazardous dispersible zinc ash and residue
B1090Specification-grade batteries without lead, cadmium or mercury
B1100Specified metal-production residues
B1115Qualifying plastic-coated waste cable
B1120Spent solid catalysts with specified metals
B1130Cleaned spent precious-metal catalyst
B1140Solid precious-metal residue with trace cyanide