Waste code for used oil Spent crankcase oil & lubricants, sometimes PCB-tainted.
- Free, no account
- Based on official federal and provincial sources
- Nothing is stored
Find a Canadian waste code
Used oil: 17 codes.
Used oil
Oil type, PCB content and water content distinguish the choices. Deciding facts and exclusions.
Ontario organic wastes
Crankcase oil and lubricants
Original lubrication service
When to use 252Manitoba organic wastes
Crankcase oil and lubricants
Original lubrication service
When to use 252Alberta industrial organic waste categories
Crankcase oil and lubricants
Original lubrication service
When to use 252Ontario organic wastes
PCB waste
PCB result and Regulation 362 form
When to use 243Manitoba organic wastes
PCB waste
PCB result and EHS133 language conflict
When to use 243Alberta industrial organic waste categories
PCB waste
PCB mass concentration
When to use 243Quebec mineral oils and grease
Low-PCB used oil
Used oil with no more than 3 mg/kg PCB
When to use A01Quebec mineral oils and grease
Used oil, intermediate PCB level
Used oil above 3 mg/kg and no higher than 50 mg/kg PCB
When to use A02Quebec PCB-bearing hazardous materials
Lower-concentration PCB liquids
Liquid in the official 50–10,000 mg/kg PCB band; endpoint operators are unsettled
When to use J01Quebec PCB-bearing hazardous materials
Higher-concentration PCB liquids
Liquid with PCB at 10,000 mg/kg or more
When to use J02Basel Y waste stream codes
Discarded mineral oil
Whether mineral oil can still serve its original purpose
When to use Y8Alberta oilfield waste codes
Hydrocarbon or synthetic lubricating oil
Previous use for lubrication
When to use LUBOILAlberta oilfield waste codes
Hydraulic or transmission oil
Previous hydraulic or transmission service
When to use HYDOILB.C. hazardous-waste definition routes
Waste oil
Oil concentration and original-use suitability
When to use Definition (d)Manitoba Schedule B concentration codes
PCBs (polychlorinated biphenyls)
PCB mass concentration; bilingual limits differ
When to use EHS133Manitoba Schedule A hazardous wastes
Oil no longer suitable for its original use
Original lubrication use and present suitability
When to use MHW1Quebec mineral oils and grease
Oily water and emulsions
Water phase or emulsified form
When to use A03
Other codes that mention it 10
B.C. Schedule 7 wastes
Cyanide heat-treatment oil-bath sludge
When to use Type 11Basel List B codes
Non-hazardous used edible fats and oils
When to use B3065Federal F source codes
Cyanide heat-treatment oil-bath sludge
When to use F010Federal HAZ codes
Used lubricating oil loads of 500 L or more
When to use HAZ2Federal HAZ codes
Used oil filters containing more than 6% oil
When to use HAZ3Federal recycling operation codes
Re-refining or re-use of used oil
When to use R9Ontario F-series hazardous industrial wastes
Cyanide heat-treatment oil-bath sludge
Quebec mineral oils and grease
Used oil filters
When to use A05
Which Canadian codes fit used oil?
| Candidate | Place | Waste stream |
|---|---|---|
| 252 | Ontario | Crankcase oil or lubricants |
| 252 | Manitoba | Crankcase oil or lubricants |
| 252 | Alberta | Crankcase oil or lubricants |
| 243 | Ontario | PCB waste |
| 243 | Manitoba | PCB waste |
| 243 | Alberta | PCB waste |
| A01 | Quebec | Low-PCB used oil |
| A02 | Quebec | Used oil, intermediate PCB level |
| J01 | Quebec | Lower-concentration PCB liquids |
| J02 | Quebec | Higher-concentration PCB liquids |
| Y8 | Federal | Discarded mineral oil |
| LUBOIL | Alberta | Hydrocarbon or synthetic lubricating oil |
| HYDOIL | Alberta | Hydraulic or transmission oil |
| Definition (d) | British Columbia | Waste oil |
| EHS133 | Manitoba | PCBs (polychlorinated biphenyls) |
| MHW1 | Manitoba | Oil no longer suitable for its original use |
| A03 | Quebec | Oily water and emulsions |
What tells used oil codes apart?
Ontario gives crankcase oil and lubricants, oil-water separator sludge, emulsified cutting oil and oil bulked at a transfer site different classes. In Quebec the PCB concentration separates used-oil categories from the PCB categories.
Quebec A01 includes 3 mg/kg of PCBs. A02 starts above 3 mg/kg and includes 50 mg/kg. At 50 mg/kg, compare the group J wording too.
How should used oil be described for collection in Canada?
Keep the oil, oily water, filters and absorbents identifiable. A used-oil category is not a TDG class and doesn't mean the oil is ignitable.
| Exclusions and shipment rules |
|---|
| Alberta |
| British Columbia |
| Manitoba |
| Northwest Territories |
| Nova Scotia |
| Nunavut |
| Ontario |
| Prince Edward Island |
| Quebec |
| Yukon |
When is used oil excluded or below the paperwork threshold in Canada?
| Place | Exclusions, thresholds and applicable routes |
|---|---|
| British Columbia | Oil mixtures at 3% by weight or less don't meet the waste-oil definition. Still check for other hazardous traits and describe oily water separately. This doesn't remove TDG duties. s. 1, waste oil definition |
| Quebec | Synthetic oils made mainly of fatty-acid esters are excluded from the used-oil assimilation rule in article 4(1). Check whether another hazard or assimilation rule still applies. art. 4(1) |
Sources
- Directive 058: Oilfield Waste Management Requirements for the Upstream Petroleum Industry
- Industrial Waste Identification and Management Options
- Hazardous Waste Regulation, Schedule 7
- Guide to hazardous waste and hazardous recyclable materials classification
- Hazardous Waste Generator Registration: provincial waste class code table
- Hazardous Waste Regulation, M.R. 195/2015
- Registration guidance manual, Appendix A: Ontario waste classes
- Regulation 362: Waste Management — PCBs
- Quebec hazardous-material management rules — Schedule 4 categories
- Quebec examples of residual hazardous-material identification