Skip to content

10 01 09* EWC code (100109) Strong corrosive acid from power plant processes.

  • Free, no account
  • Based on the UK List of Waste and WM3
  • Search in plain words or codes

Find an EWC code

10 01 09*, hazardous.

  • HazardousPower stations and boilers

    Sulphuric acid

Hazardous sulphuric acid, a strong corrosive acid arising at power stations & other combustion plants from flue gas work.

Is 10 01 09* hazardous?

Yes, always. 10 01 09* has an asterisk, and WM3 lists it as absolute hazardous. Waste under this code is hazardous whatever is in it, so no assessment can change that.

It moves on a hazardous waste consignment note, not a waste transfer note. Hazardous waste EWC codes

What does 10 01 09* cover?

Official wording
“sulphuric acid”
Sub-chapter
10 01 Wastes from power stations and other combustion plants (except 19)
Chapter
10 Wastes from thermal processes

Which other codes sit beside 10 01 09*?

These codes share sub-chapter 10 01 with it.

CodeWhat it isHazardous
10 01 01Bottom ash, slag and boiler dustNo
10 01 02Coal fly ashNo
10 01 03Fly ash from peat and untreated woodNo
10 01 04*Oil fly ash and boiler dustYes
10 01 05Calcium-based reaction waste from flue-gas desulphurisation in solid formNo
10 01 07Calcium-based reaction waste from flue-gas desulphurisation in sludge formNo
10 01 13*Fly ash from emulsified hydrocarbons used as fuelYes
10 01 14*Bottom ash, slag and boiler dust from co-incineration containing hazardous substancesYes
10 01 15Bottom ash, slag and boiler dust from co-incinerationNo
10 01 16*Fly ash from co-incineration containing hazardous substancesYes
10 01 17Fly ash from co-incinerationNo
10 01 18*Waste from gas cleaning containing hazardous substancesYes
10 01 19Waste from gas cleaningNo
10 01 20*Sludges from on-site effluent treatment containing hazardous substancesYes
10 01 21Sludges from on-site effluent treatmentNo
10 01 22*Aqueous sludges from boiler cleansing containing hazardous substancesYes
10 01 23Aqueous sludges from boiler cleansingNo
10 01 24Sands from fluidised bedsNo
10 01 25Waste from fuel storage and preparation of coal-fired power plantsNo
10 01 26Waste from cooling-water treatmentNo
10 01 99Waste not otherwise specifiedNo

Sources

The codes apply across the UK. The consignment note here is for England and Wales. Scotland and Northern Ireland have their own.