K001 RCRA waste code Sludge from wood-preserving wastewater tanks.
- Free, no account
- Based on 40 CFR 261.32 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
K001, Bottom sludge from treating wood-preserving wastewater.
K-listed waste
Bottom sludge from treating wood-preserving wastewater
Industry: Wood preservation.
Is K001 hazardous waste?
Yes. K001 is a nonacute K-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code T for toxicity.
K001 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put K001 in Item 13. Look up the VSQG exemptions and empty-container rules too.
What does K001 cover?
Bottom sediment sludge from treating wood-preserving wastewater, where the process uses creosote, pentachlorophenol or both. The waste form and its source process must both match the K-list wording.
- Hazard code
- T for toxicity
- Industry
- Wood preservation
- Rule
- 40 CFR 261.32
Is wood-preserving wastewater bottom sludge K001 or another code?
| Code | When it fits |
|---|---|
| K001 | Bottom sediment sludge from treating wood-preserving wastewater where the process uses creosote, pentachlorophenol or both. |
The industry, production step and waste form pick the K listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.
What makes K001 source-specific?
K001 covers only the named waste form from the named wood preserving operation. Other wastes from that industry need their own listing check, and an unlisted waste still has to be checked for hazardous characteristics.
Which wastes take K001?
| Waste | When it’s K001 |
|---|---|
| Wood-preserving wastewater sludge | Bottom sediment sludge comes from wastewater treatment for wood-preserving processes using creosote or pentachlorophenol |
Sources
- 40 CFR 261.32 — Hazardous wastes from specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers
ComplyOnSite