RCRA waste codes for parts washer solvent Used degreasing fluid from workshop parts washers.
- Free, no account
- Based on 40 CFR Part 261 and EPA guidance
- Nothing is stored
Find a federal hazardous waste code
Parts washer solvent: 11 codes.
Parts washer solvent
The original formulation and use decide an F listing. Testing or reliable knowledge decides characteristic codes. See the parts washer solvent guide for exclusions and management routes.
F-listed waste
Spent halogenated solvents used for degreasing
The washer removed grease using an original formulation covered by F001
When to use F001F-listed waste
Spent halogenated solvents
The washer's original formula meets F002 composition conditions regardless of degreasing use
When to use F002F-listed waste
Spent non-halogenated solvents: acetone, xylene and related solvents
Washer fluid was used neat or in a blend meeting F003 before-use conditions
When to use F003F-listed waste
Spent cresol, cresylic acid and nitrobenzene solvents
The original washer formula meets F004's named-solvent or blend test
When to use F004F-listed waste
Spent toluene, methyl ethyl ketone (MEK) and related solvents
Before-use ingredients meet F005 composition conditions for the spent washer fluid
When to use F005Characteristic hazardous waste
Ignitable waste
A representative spent-fluid sample meets the flash-point criterion or another D001 physical-form test
When to use D001Characteristic hazardous waste
Benzene
Benzene leaching from parts washer solvent reaches the TCLP limit
When to use D018Characteristic hazardous waste
Carbon tetrachloride
Carbon tetrachloride leaching from parts washer solvent reaches the TCLP limit
When to use D019Characteristic hazardous waste
Chlorobenzene
Chlorobenzene leaching from parts washer solvent reaches the TCLP limit
When to use D021Characteristic hazardous waste
Tetrachloroethylene
Tetrachloroethylene leaching from parts washer solvent reaches the TCLP limit
When to use D039Characteristic hazardous waste
Trichloroethylene
Trichloroethylene leaching from parts washer solvent reaches the TCLP limit
When to use D040
Which RCRA codes apply to parts washer solvent?
The original formulation and use decide an F listing. Characteristic codes come from testing or reliable knowledge.
| Code | When it applies |
|---|---|
| F001 | The washer removed grease with an original formulation that falls under F001 |
| F002 | The washer's original formula meets the F002 composition conditions, whether or not it degreased |
| F003 | Washer fluid was used neat or in a blend that meets the F003 before-use conditions |
| F004 | The original formula meets F004's named-solvent or blend test |
| F005 | The before-use ingredients meet the F005 composition conditions |
| D001 | A representative sample of the spent fluid meets the flash-point criterion or another D001 physical-form test |
| D018 | Benzene in the leachate reaches the TCLP limit |
| D019 | Carbon tetrachloride in the leachate reaches the TCLP limit |
| D021 | Chlorobenzene in the leachate reaches the TCLP limit |
| D039 | Tetrachloroethylene in the leachate reaches the TCLP limit |
| D040 | Trichloroethylene in the leachate reaches the TCLP limit |
How do I prove the code for parts washer solvent?
Record whether the washer was used for degreasing. Assess an aqueous cleaner from its ingredients and contamination.
Is there another way to manage parts washer solvent?
Check the Loss-of-characteristic rule for another route.