F002 RCRA waste code Used chlorinated solvents, such as methylene chloride.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F002, Spent halogenated solvents.
F-listed waste
Spent halogenated solvents
F-list process waste.

Is F002 hazardous waste?
Yes. F002 is nonacute F-listed hazardous waste when the source process and waste stream match the listing. The federal table gives it hazard code (T), meaning toxicity.
F002 depends on how and where the waste arose, not on a concentration test alone. A test may add a characteristic code, but it doesn't remove this listing when its conditions are met.
On a required hazardous waste manifest, put F002 in Item 13. See VSQG exemptions and empty-container rules.
What does F002 cover?
F002 covers spent tetrachloroethylene, methylene chloride, trichloroethylene, 1,1,1-trichloroethane, chlorobenzene, 1,1,2-trichloro-1,2,2-trifluoroethane, ortho-dichlorobenzene, trichlorofluoromethane or 1,1,2-trichloroethane. It also covers blends that held at least 10% by volume of any F001, F002, F004 or F005 solvent before use. Still bottoms from recovering these spent solvents or blends are included.
- Hazard code
- (T), toxicity
- Rule
- 40 CFR 261.31
Is spent halogenated solvent F002 or F001?
| Code | When it fits |
|---|---|
| F002 | A named halogenated solvent was spent in solvent use. Blend and still-bottom conditions can also apply, and F001 may overlap. |
| F001 | A listed solvent was used for degreasing, or the qualifying degreasing blend or recovery still-bottom conditions apply. |
| F003 | A listed nonhalogenated solvent was spent, and the neat-solvent, before-use blend or recovery still-bottom conditions apply. |
| F004 | Cresol, cresylic acid or nitrobenzene was spent as solvent, or the qualifying blend or recovery still-bottom conditions apply. |
| F005 | A named nonhalogenated solvent was spent, or the qualifying before-use blend or recovery still-bottom conditions apply. |
Solvent use, what the solvent held before use, and the recovery-residue rule decide among F001–F005. The rows don't replace checking each listing or characteristic that applies on its own. One waste can carry more than one federal code.
Which wastes take F002?
| Waste | When it’s F002 |
|---|---|
| Paint stripping waste | The stripping solvent’s original recipe meets F002 composition conditions |
| Used oil | Mixing introduced spent halogenated solvent named in F002 |
| Radiator repair waste | Radiator cleaning used solvent meeting F002 before-use conditions |
| Shop drain and sump sludge | The sludge contains solvent meeting F002 before-use conditions |
| Vehicle wash wastewater | The wastewater contains solvent meeting F002 before-use conditions |
| Spent solvents | Used solvent in spent solvents meets F002 before-use conditions regardless of degreasing use |
| Parts washer solvent | The washer's original formula meets F002 composition conditions regardless of degreasing use |
| Solvent still bottoms | Still bottoms come from recovery of F002 spent solvent |
Which codes sit beside F002?
| Code | What it is |
|---|---|
| F006 | Wastewater sludge from electroplating |
| F007 | Spent cyanide plating-bath solution |
| F008 | Bottom residue from cyanide plating baths |
| F009 | Spent cyanide baths used to strip or clean plated metal |
| F010 | Residue from cyanide oil-quench baths used in metal heat treating |
| F011 | Spent cyanide solution from cleaning heat-treatment salt pots |
| F012 | Wastewater sludge from cyanide metal-quench baths |
| F019 | Wastewater sludge from aluminum conversion coating |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers