F009 RCRA waste code Used cyanide stripping & cleaning baths.

  • Free, no account
  • Based on 40 CFR 261.31 and EPA hazardous-waste rules
  • Nothing is stored

Find a federal hazardous waste code

F009, Spent cyanide baths used to strip or clean plated metal.

  • F-listed waste

    Spent cyanide baths used to strip or clean plated metal

F-list process waste.

Reactive & toxic F-listed waste. Spent cyanide solutions used to strip or clean plated metal, which can release poison gas with acid.

Is F009 hazardous waste?

Yes. F009 is nonacute F-listed hazardous waste when the source process and waste stream match the listing. The federal table gives it hazard code (R, T), meaning reactivity and toxicity.

F009 depends on how and where the waste arose, not on a concentration test alone. A test may add a characteristic code, but it doesn't remove this listing when its conditions are met.

On a required hazardous waste manifest, put F009 in Item 13. See VSQG exemptions and empty-container rules.

What does F009 cover?

F009 covers spent stripping and cleaning bath solutions from electroplating operations from a process that uses cyanide. The waste form and its exact source process must both match, because chemical content alone isn't enough.

Hazard code
(R, T), reactivity and toxicity

Is cyanide stripping or cleaning bath F009 or F010?

CodeWhen it fits
F009It is spent stripping and cleaning bath solutions from electroplating operations from a process that uses cyanide.
F010It is quenching bath residues from oil baths from metal heat treating operations from a process that uses cyanide.
F008It is plating bath residues from the bottom of plating baths from electroplating operations from a process that uses cyanide.

The operation and the waste form set this listing apart. Chemical content alone doesn't pick an F code. The rows show nearby listed streams, not every code that can apply, so add any characteristic or other listing that fits on its own. One waste can carry more than one federal code.

Which wastes take F009?

WasteWhen it’s F009
Cyanide electroplating rinse sludge and bath wasteIt is spent cyanide stripping or cleaning-bath solution. Rinsewater sludge is not F009

Which codes sit beside F009?

CodeWhat it is
F004Spent cresol, cresylic acid and nitrobenzene solvents
F005Spent toluene, methyl ethyl ketone (MEK) and related solvents
F006Wastewater sludge from electroplating
F007Spent cyanide plating-bath solution
F011Spent cyanide solution from cleaning heat-treatment salt pots
F012Wastewater sludge from cyanide metal-quench baths
F019Wastewater sludge from aluminum conversion coating
F020Waste from making or manufacturing use of tri- or tetrachlorophenol