F010 RCRA waste code Residue from quenching hot metal in cyanide oil baths.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F010, Residue from cyanide oil-quench baths used in metal heat treating.
F-listed waste
Residue from cyanide oil-quench baths used in metal heat treating
F-list process waste.
Is F010 hazardous waste?
Yes. F010 is nonacute F-listed hazardous waste when the source process and waste stream match the listing. The federal table gives it hazard code (R, T), meaning reactivity and toxicity.
F010 depends on how and where the waste arose, not on a concentration test alone. A test may add a characteristic code, but it doesn't remove this listing when its conditions are met.
On a required hazardous waste manifest, put F010 in Item 13. See VSQG exemptions and empty-container rules.
What does F010 cover?
F010 covers quenching bath residues from oil baths from metal heat treating operations from a process that uses cyanide. The waste form and its exact source process must both match, because chemical content alone isn't enough.
- Hazard code
- (R, T), reactivity and toxicity
- Rule
- 40 CFR 261.31
Is cyanide oil-quench residue F010 or F012?
| Code | When it fits |
|---|---|
| F010 | It is quenching bath residues from oil baths from metal heat treating operations from a process that uses cyanide. |
| F012 | It is quenching waste water treatment sludges from metal heat treating operations from a process that uses cyanide. |
| F009 | It is spent stripping and cleaning bath solutions from electroplating operations from a process that uses cyanide. |
The operation and the waste form set this listing apart. Chemical content alone doesn't pick an F code. The rows show nearby listed streams, not every code that can apply, so add any characteristic or other listing that fits on its own. One waste can carry more than one federal code.
Which wastes take F010?
| Waste | When it’s F010 |
|---|---|
| Cyanide heat-treatment waste | It is quenching-bath residue from oil baths used in metal heat treating where cyanides are used |
Which codes sit beside F010?
| Code | What it is |
|---|---|
| F005 | Spent toluene, methyl ethyl ketone (MEK) and related solvents |
| F006 | Wastewater sludge from electroplating |
| F007 | Spent cyanide plating-bath solution |
| F008 | Bottom residue from cyanide plating baths |
| F011 | Spent cyanide solution from cleaning heat-treatment salt pots |
| F019 | Wastewater sludge from aluminum conversion coating |
| F020 | Waste from making or manufacturing use of tri- or tetrachlorophenol |
| F021 | Waste from making or manufacturing use of pentachlorophenol |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers