F012 RCRA waste code Sludge from quench wastewater at cyanide heat-treating.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F012, Wastewater sludge from cyanide metal-quench baths.
F-listed waste
Wastewater sludge from cyanide metal-quench baths
F-list process waste.
Is F012 hazardous waste?
Yes. F012 is a nonacute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code T for toxicity.
F012 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F012 in Item 13. Look up the VSQG exemptions and empty-container rules too.
What does F012 cover?
Sludge from treating quench wastewater in metal heat treating, where the process uses cyanide. The waste form and its source process must both match the F-list wording.
- Hazard code
- T for toxicity
- Rule
- 40 CFR 261.31
Is cyanide quench wastewater sludge F012, F010 or F011?
| Code | When it fits |
|---|---|
| F012 | Quenching waste water treatment sludges from metal heat treating operations from a process that uses cyanide. |
| F010 | Quenching bath residues from oil baths from metal heat treating operations from a process that uses cyanide. |
| F011 | Spent cyanide solutions from salt bath pot cleaning from metal heat treating operations. |
The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.
Which wastes take F012?
| Waste | When it’s F012 |
|---|---|
| Cyanide heat-treatment waste | Quenching wastewater treatment sludge from metal heat treating where cyanides are used |
Which codes sit beside F012?
| Code | What it is |
|---|---|
| F007 | Spent cyanide plating-bath solution |
| F008 | Bottom residue from cyanide plating baths |
| F009 | Spent cyanide baths used to strip or clean plated metal |
| F019 | Wastewater sludge from aluminum conversion coating |
| F020 | Waste from making or manufacturing use of tri- or tetrachlorophenol |
| F021 | Waste from making or manufacturing use of pentachlorophenol |
| F022 | Waste from using chlorobenzenes under alkaline conditions |
| F023 | Waste from equipment formerly used for chlorophenols |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers