F021 RCRA waste code Acute waste from making or using a wood preservative.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F021, Waste from making or manufacturing use of pentachlorophenol.
Acute hazardousF-listed waste
Waste from making or manufacturing use of pentachlorophenol
F-list process waste.
Is F021 hazardous waste?
Yes. F021 is an acute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code H for acute hazard.
F021 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F021 in Item 13. Look up the VSQG exemptions and empty-container rules too.
What does F021 cover?
Waste from making pentachlorophenol, or from using it in manufacturing as a reactant, intermediate or part of a formulating process. It also covers intermediates used to make its derivatives. It excludes wastewater and spent carbon from hydrogen chloride purification.
- Hazard code
- H for acute hazard
- Rule
- 40 CFR 261.31
Is pentachlorophenol process waste F021, F020 or F023?
| Code | When it fits |
|---|---|
| F021 | Waste from making pentachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process. |
| F020 | Waste from making tri- or tetrachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process. |
| F023 | Material was made on equipment formerly used to make or use tri- or tetrachlorophenol in manufacturing. |
The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.
Which wastes take F021?
| Waste | When it’s F021 |
|---|---|
| Dioxin-listed process waste | Production or manufacturing use involved pentachlorophenol or intermediates for its derivatives |
Which codes sit beside F021?
| Code | What it is |
|---|---|
| F010 | Residue from cyanide oil-quench baths used in metal heat treating |
| F011 | Spent cyanide solution from cleaning heat-treatment salt pots |
| F012 | Wastewater sludge from cyanide metal-quench baths |
| F019 | Wastewater sludge from aluminum conversion coating |
| F022 | Waste from using chlorobenzenes under alkaline conditions |
| F024 | Process residues from making certain chlorinated hydrocarbons |
| F025 | Filters, drying agents and light residues from chlorinated hydrocarbons |
| F026 | Waste from equipment formerly used with alkaline chlorobenzenes |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers