Skip to content

RCRA waste code finder

F021 RCRA waste code Acute waste from making or using a wood preservative.

  • Free, no account
  • Based on 40 CFR 261.31 and EPA hazardous-waste rules
  • Nothing is stored

Find a federal hazardous waste code

F021, Waste from making or manufacturing use of pentachlorophenol.

  • Acute hazardousF-listed waste

    Waste from making or manufacturing use of pentachlorophenol

F-list process waste.

Acute hazardous F-listed waste. Residues from making or using pentachlorophenol, or the derivatives made from it.

Is F021 hazardous waste?

Yes. F021 is an acute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code H for acute hazard.

F021 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F021 in Item 13. Look up the VSQG exemptions and empty-container rules too.

What does F021 cover?

Waste from making pentachlorophenol, or from using it in manufacturing as a reactant, intermediate or part of a formulating process. It also covers intermediates used to make its derivatives. It excludes wastewater and spent carbon from hydrogen chloride purification.

Hazard code
H for acute hazard

Is pentachlorophenol process waste F021, F020 or F023?

CodeWhen it fits
F021Waste from making pentachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process.
F020Waste from making tri- or tetrachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process.
F023Material was made on equipment formerly used to make or use tri- or tetrachlorophenol in manufacturing.

The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.

Which wastes take F021?

WasteWhen it’s F021
Dioxin-listed process wasteProduction or manufacturing use involved pentachlorophenol or intermediates for its derivatives

Which codes sit beside F021?

CodeWhat it is
F010Residue from cyanide oil-quench baths used in metal heat treating
F011Spent cyanide solution from cleaning heat-treatment salt pots
F012Wastewater sludge from cyanide metal-quench baths
F019Wastewater sludge from aluminum conversion coating
F022Waste from using chlorobenzenes under alkaline conditions
F024Process residues from making certain chlorinated hydrocarbons
F025Filters, drying agents and light residues from chlorinated hydrocarbons
F026Waste from equipment formerly used with alkaline chlorobenzenes