Skip to content

RCRA waste code finder

F025 RCRA waste code Filter & drying-agent waste from chlorinated hydrocarbons.

  • Free, no account
  • Based on 40 CFR 261.31 and EPA hazardous-waste rules
  • Nothing is stored

Find a federal hazardous waste code

F025, Filters, drying agents and light residues from chlorinated hydrocarbons.

  • F-listed waste

    Filters, drying agents and light residues from chlorinated hydrocarbons

F-list process waste.

Toxic F-listed waste. Condensed light ends, spent filters & spent desiccants from making short-chain chlorinated hydrocarbons.

Is F025 hazardous waste?

Yes. F025 is a nonacute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code T for toxicity.

F025 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F025 in Item 13. Look up the VSQG exemptions and empty-container rules too.

What does F025 cover?

Condensed light ends, spent filters, filter aids and spent desiccant from making chlorinated aliphatic hydrocarbons with 1 to 5 carbons by the free-radical process.

Hazard code
T for toxicity

Is chlorinated hydrocarbon filter waste F025 or F024?

CodeWhen it fits
F025Condensed light ends, spent filters, filter aids or spent desiccant from free-radical production of chlorinated aliphatic hydrocarbons with 1 to 5 carbons.
F024Process waste from free-radical production of chlorinated aliphatic hydrocarbons with 1 to 5 carbons.

The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.

Which wastes take F025?

WasteWhen it’s F025
Dioxin-listed process wasteLight end, spent filter, filter aid or desiccant from chlorinated aliphatic hydrocarbon production

Which codes sit beside F025?

CodeWhat it is
F020Waste from making or manufacturing use of tri- or tetrachlorophenol
F021Waste from making or manufacturing use of pentachlorophenol
F022Waste from using chlorobenzenes under alkaline conditions
F023Waste from equipment formerly used for chlorophenols
F026Waste from equipment formerly used with alkaline chlorobenzenes
F027Unused chlorophenol formulations
F028Residue from heat-treating soil contaminated with listed dioxin waste
F032Waste from wood preserving with chlorophenol products