F024 RCRA waste code Process residue from making chlorinated hydrocarbons.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F024, Process residues from making certain chlorinated hydrocarbons.
F-listed waste
Process residues from making certain chlorinated hydrocarbons
F-list process waste.
Is F024 hazardous waste?
Yes. F024 is a nonacute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code T for toxicity.
F024 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F024 in Item 13. Look up the VSQG exemptions and empty-container rules too.
What does F024 cover?
Process waste from making chlorinated aliphatic hydrocarbons with 1 to 5 carbons by the free-radical process. It includes distillation residue, heavy ends, tar and reactor cleanout waste. It excludes wastewater, wastewater treatment sludge, spent catalyst and waste already listed in 261.31 or 261.32.
- Hazard code
- T for toxicity
- Rule
- 40 CFR 261.31
Is chlorinated hydrocarbon process residue F024 or F025?
| Code | When it fits |
|---|---|
| F024 | Process waste from free-radical production of chlorinated aliphatic hydrocarbons with 1 to 5 carbons. |
| F025 | Condensed light ends, spent filters, filter aids or spent desiccant from free-radical production of chlorinated aliphatic hydrocarbons with 1 to 5 carbons. |
The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.
Which wastes take F024?
| Waste | When it’s F024 |
|---|---|
| Dioxin-listed process waste | A free-radical process made C1–C5 chlorinated aliphatic hydrocarbons and generated the residue |
Which codes sit beside F024?
| Code | What it is |
|---|---|
| F019 | Wastewater sludge from aluminum conversion coating |
| F020 | Waste from making or manufacturing use of tri- or tetrachlorophenol |
| F021 | Waste from making or manufacturing use of pentachlorophenol |
| F022 | Waste from using chlorobenzenes under alkaline conditions |
| F023 | Waste from equipment formerly used for chlorophenols |
| F026 | Waste from equipment formerly used with alkaline chlorobenzenes |
| F027 | Unused chlorophenol formulations |
| F028 | Residue from heat-treating soil contaminated with listed dioxin waste |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers
ComplyOnSite