Skip to content

RCRA waste code finder

F022 RCRA waste code Acute waste from alkaline chlorobenzene reactions.

  • Free, no account
  • Based on 40 CFR 261.31 and EPA hazardous-waste rules
  • Nothing is stored

Find a federal hazardous waste code

F022, Waste from using chlorobenzenes under alkaline conditions.

  • Acute hazardousF-listed waste

    Waste from using chlorobenzenes under alkaline conditions

F-list process waste.

Acute hazardous F-listed waste. Residues from making tetra-, penta- or hexachlorobenzenes under alkaline conditions.

Is F022 hazardous waste?

Yes. F022 is an acute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code H for acute hazard.

F022 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F022 in Item 13. Look up the VSQG exemptions and empty-container rules too.

What does F022 cover?

Waste from using tetra-, penta- or hexachlorobenzene under alkaline conditions in manufacturing, as a reactant, intermediate or part of a formulating process. It excludes wastewater and spent carbon from hydrogen chloride purification.

Hazard code
H for acute hazard

Is alkaline chlorobenzene waste F022, F026 or F021?

CodeWhen it fits
F022Waste from manufacturing use of tetra-, penta- or hexachlorobenzene under alkaline conditions as a reactant, intermediate or component of a formulating process.
F026Material was made on equipment formerly used with tetra-, penta- or hexachlorobenzene under alkaline manufacturing conditions.
F021Waste from making pentachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process.

The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.

Which wastes take F022?

WasteWhen it’s F022
Dioxin-listed process wasteManufacturing used tetra-, penta- or hexachlorobenzenes under alkaline conditions

Which codes sit beside F022?

CodeWhat it is
F011Spent cyanide solution from cleaning heat-treatment salt pots
F012Wastewater sludge from cyanide metal-quench baths
F019Wastewater sludge from aluminum conversion coating
F020Waste from making or manufacturing use of tri- or tetrachlorophenol
F023Waste from equipment formerly used for chlorophenols
F024Process residues from making certain chlorinated hydrocarbons
F025Filters, drying agents and light residues from chlorinated hydrocarbons