F022 RCRA waste code Acute waste from alkaline chlorobenzene reactions.
- Free, no account
- Based on 40 CFR 261.31 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
F022, Waste from using chlorobenzenes under alkaline conditions.
Acute hazardousF-listed waste
Waste from using chlorobenzenes under alkaline conditions
F-list process waste.
Is F022 hazardous waste?
Yes. F022 is an acute F-listed hazardous waste when the named source process and waste stream match. The federal table gives it hazard code H for acute hazard.
F022 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test can add a characteristic code but doesn't remove the listing once its conditions are met. On a required hazardous waste manifest, put F022 in Item 13. Look up the VSQG exemptions and empty-container rules too.
What does F022 cover?
Waste from using tetra-, penta- or hexachlorobenzene under alkaline conditions in manufacturing, as a reactant, intermediate or part of a formulating process. It excludes wastewater and spent carbon from hydrogen chloride purification.
- Hazard code
- H for acute hazard
- Rule
- 40 CFR 261.31
Is alkaline chlorobenzene waste F022, F026 or F021?
| Code | When it fits |
|---|---|
| F022 | Waste from manufacturing use of tetra-, penta- or hexachlorobenzene under alkaline conditions as a reactant, intermediate or component of a formulating process. |
| F026 | Material was made on equipment formerly used with tetra-, penta- or hexachlorobenzene under alkaline manufacturing conditions. |
| F021 | Waste from making pentachlorophenol, or using it in manufacturing as a reactant, intermediate or component of a formulating process. |
The operation and waste form pick the listing, not the chemical content alone. The rows show nearby listed streams, not every code that could apply. Add any characteristic or other listing that also fits, since one waste can carry more than 1 federal code.
Which wastes take F022?
| Waste | When it’s F022 |
|---|---|
| Dioxin-listed process waste | Manufacturing used tetra-, penta- or hexachlorobenzenes under alkaline conditions |
Which codes sit beside F022?
| Code | What it is |
|---|---|
| F011 | Spent cyanide solution from cleaning heat-treatment salt pots |
| F012 | Wastewater sludge from cyanide metal-quench baths |
| F019 | Wastewater sludge from aluminum conversion coating |
| F020 | Waste from making or manufacturing use of tri- or tetrachlorophenol |
| F023 | Waste from equipment formerly used for chlorophenols |
| F024 | Process residues from making certain chlorinated hydrocarbons |
| F025 | Filters, drying agents and light residues from chlorinated hydrocarbons |
| F027 | Unused chlorophenol formulations |
Sources
- 40 CFR 261.31 — Hazardous wastes from non-specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers