Skip to content

RCRA waste code finder

K110 RCRA waste code Condensed vapors from the middle separation step of rocket-fuel chemical.

  • Free, no account
  • Based on 40 CFR 261.32 and EPA hazardous-waste rules
  • Nothing is stored

Find a federal hazardous waste code

K110, Condensed intermediate-separation vapors from making UDMH.

  • K-listed waste

    Condensed intermediate-separation vapors from making UDMH

Industry: Organic chemicals.

Toxic K-listed waste from organic chemical plants. Condensed column overheads from separating intermediates when UDMH is made.

Is K110 hazardous waste?

Yes. K110 is a nonacute K-listed hazardous waste when the source process and waste stream match. Its federal hazard code is (T), for toxicity.

K110 is listed by source, so how and where the waste arose decides it, not a concentration test alone. A test may add a characteristic code but doesn't remove the listing. On a required hazardous waste manifest, put K110 in Item 13. See VSQG exemptions and empty-container rules.

What does K110 cover?

Condensed column overheads from the intermediate separation step when making 1,1-dimethylhydrazine (UDMH) from carboxylic acid hydrazides. The waste form and its exact source process must both match. Chemical content alone isn't enough.

Hazard code
(T), toxicity
Industry
Organic chemicals

Is UDMH intermediate-separation condensate K110 or another code?

CodeWhen it fits
K110It is condensed column overheads from intermediate separation in making 1,1-dimethylhydrazine (UDMH) from carboxylic acid hydrazides.
K108It is condensed column overheads from product separation and condensed reactor vent gases in making 1,1-dimethylhydrazine (UDMH) from carboxylic acid hydrazides.
K107It is column bottoms from product separation in making 1,1-dimethylhydrazine (UDMH) from carboxylic acid hydrazides.

The industry, production step and waste form tell these K listings apart. The rows show nearby listed streams, not every code that can apply. Add any characteristic or other listing that also fits, as one waste can carry more than 1 federal code.

Which codes sit beside K110?

CodeWhat it is
K105Separated reactor-wash water from making chlorobenzenes
K106Wastewater sludge from mercury-cell chlorine production
K109Spent purification filters from making rocket-fuel chemical UDMH
K111Product washwater from making dinitrotoluene
K112Drying-column water from making toluenediamine
K113Condensed light fractions from purifying toluenediamine
K114Ortho-isomer residue from purifying toluenediamine
K115Heavy residue from purifying toluenediamine