Skip to content

RCRA waste code finder

U051 RCRA waste code Tar-like wood preservative used on fences & railway sleepers.

  • Free, no account
  • Based on 40 CFR 261.33 and EPA guidance
  • Nothing is stored

Find a federal hazardous waste code

U051, Creosote.

  • U-listed waste

    Creosote

U-list unused product.

U-listed hazardous waste for unused creosote, a coal tar wood preservative used on poles & sleepers.

Is U051 hazardous waste?

Yes, when the listing applies. U051 covers creosote thrown away unused, including off-specification product and qualifying residues. It is a U-listed waste, not an acute P-listed one. The listing depends on the product and how it is discarded, not on a TCLP result alone.

U051 is nonacute hazardous waste. On a required hazardous waste manifest, put U051 in Item 13. VSQG exemptions and empty-container rules and pharmaceutical containers still apply.

What does U051 cover?

This covers creosote discarded unused, either pure or technical grade or as the only active ingredient in a formulation. It also covers off-specification batches, residues in nonempty containers and spill cleanup residues of those products. Inactive ingredients in the formulation don't affect this.

CAS
not provided
Table entries
Creosote
Hazard codes in the record
T (toxic)

Is waste creosote always U051?

CodeWhen it fits
U051The unused chemical is thrown away, pure or technical grade or as the sole active ingredient. Residues from those products count too.
Characteristic waste (D001–D043)A used chemical or a different formulation shows a hazardous characteristic. Process listings can apply too.

A listed unused product can also have a characteristic, so more than one row can apply. Merely finding this chemical in a manufacturing waste doesn't make it U051. Match the waste's origin, formulation and use history. Mixing listed waste with solid waste, or treating it, generally doesn't remove the listing. That takes an exclusion, an exception or an approved delisting.

Which wastes take U051?

WasteWhen it’s U051
Unused creosoteDiscarded commercial product that is pure or technical-grade creosote, or has creosote as its sole active ingredient.