Ontario waste class E019 Organophosphate soil insecticide for crops.
- Free, no account
- Based on Ontario Regulation 347, Schedule 4
- Nothing is stored
Find a Canadian waste code
E019, Phorate.
Ontario leachate quality criteria
Phorate
Ontario TCLP limit: 0.2 mg/L for Phorate.
Is Ontario E019 hazardous waste?
Yes, when the leachate limit is met. Ontario sets the leachate limit for phorate at 0.2 mg/L in the TCLP extract. A result at 0.2 mg/L meets it, subject to the regulation’s exclusions. A concentration in the original bulk waste is a different measurement, so it can't be compared with this limit.
For a shipment of this waste, the generator enters the 3-digit class and primary characterization in the waste-number details of the Ontario hazardous waste manifest. This number names the constituent for the assessment but doesn't replace the class-and-letter waste number. Land-disposal treatment standards are assessed separately.
What does Ontario E019 cover?
This number is a limit on phorate in the extract from the Toxicity Characteristic Leaching Procedure. The limit is 0.2 mg/L. It covers leachate toxicity, whatever the source industry, container or physical form. Ontario sets treatment requirements for land disposal separately.
- Schedule
- Schedule 4
- Purpose
- Leachate-toxic classification; Schedule 5 separately sets treatment standards
- TCLP classification limit
- ≥ 0.2 mg/L
- CAS
- 298-02-2
Is phorate always Ontario E019?
| Code | When it fits |
|---|---|
| E019 | The TCLP extract holds 0.2 mg/L or more. |
| This constituent criterion not met | The TCLP extract is below 0.2 mg/L. |
A result below the limit clears this constituent only. Other constituents, characteristic hazards and listed-waste rules still need assessing. Test against the classification limit first, then the land-disposal treatment standard.
Which wastes take Ontario E019?
| Waste | When it’s E019 |
|---|---|
| Contaminated soil | When the measured extract concentration meets the individual limit. |