Skip to content

RCRA waste code finder

D002 corrosive waste Strong acids & caustics that burn skin & eat metal.

  • Free, no account
  • Based on 40 CFR Part 261 and EPA guidance
  • Nothing is stored

Find a federal hazardous waste code

1 codes match.

D002 corrosive waste 1

Characteristic hazardous waste such as battery acid & drain cleaner, from spent acids to caustic baths.

What waste is D002 corrosive waste?

An aqueous waste is D002 at pH 2 or lower, or pH 12.5 or higher. A liquid is also D002 if it corrodes SAE 1020 steel faster than 6.35 mm per year at 55°C.

How do I decide D002 corrosive waste?

Use a representative sample and the specified method. A pH strip alone doesn't make a solid D002, though some states have a solid-corrosive rule.