Skip to content

Canadian waste code finder

Manitoba waste code L15 Mineral salt from water treatment & industry. Leachate limit 150 mg/L.

  • Free, no account
  • Based on Manitoba Regulation 195/2015 and program guidance
  • Nothing is stored

Find a Canadian waste code

L15, Fluoride.

  • Manitoba Schedule C leachate codes

    Fluoride

Manitoba TCLP extract limit: 150 mg/L for Fluoride.

Mineral salt from water treatment & industry. Manitoba sets a TCLP extract limit of 150 mg/L for fluoride.

Is Manitoba L15 hazardous waste?

Yes, when the Schedule C extract limit is met. L15 is a Category 4 Provincial Waste Code. Waste is L15 when a Method 1311 extract holds fluoride at 150 mg/L or more.

The 3-digit provincial waste class goes in a separate field. It doesn't replace the UN Number or Provincial Waste Code.

For regulated hazardous waste, enter L15 in the UN Number or Provincial Waste Code field on the Manitoba movement document. Manitoba’s registration and shipment rules also apply.

What does Manitoba L15 cover?

This entry covers fluoride in a Method 1311 waste extract. A result of 150 mg/L or more meets the Schedule C limit and puts the waste in hazardous-waste Category 4.

Schedule
C
Hazardous-waste category
4
Recorded threshold
150 mg/L
Official wording
Hazardous Waste Regulation, M.R. 195/2015.php?reg=195%2F2015)

Is fluoride waste always Manitoba L15?

CodeWhen it fits
L15A Method 1311 extract holds fluoride at 150 mg/L or more.

Choose the code from what the waste holds, its test result and where it came from. Provincial registration and movement rules, federal cross-border controls and TDG classification are separate checks, and a code doesn't replace them.

Which codes sit beside Manitoba L15?

CodeWhat it is
L70Diquat
L71Diuron
L14Endrin
L102Ethylbenzene
L72Glyphosate
L16Heptachlor + Heptachlor epoxide
L73Hexachlorobenzene
L74Hexachlorobutadiene