K047 RCRA waste code Reactive pink or red water from making TNT.
- Free, no account
- Based on 40 CFR 261.32 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
K047, Pink or red wastewater from TNT operations.
K-listed waste
Pink or red wastewater from TNT operations
Industry: Explosives.
Is K047 hazardous waste?
Yes. K047 is nonacute K-listed hazardous waste when the waste comes from the named process and matches the named stream. The federal table gives it hazard code (R), reactivity.
A K listing depends on where and how the waste was made, not on a test result alone. A test may add a characteristic code, but it doesn't remove the listing.
On a required hazardous waste manifest, put K047 in Item 13. Check the VSQG exemptions and empty-container rules too.
What does K047 cover?
Pink or red water from TNT operations. The waste form and the exact source process must both match. Chemical content alone is not enough.
- Hazard code
- (R), reactivity
- Industry
- Explosives
- Rule
- 40 CFR 261.32
Is pink or red TNT wastewater always K047?
| Code | When it fits |
|---|---|
| K047 | Pink/red water from TNT operations. |
| K046 | Wastewater treatment sludges from the manufacturing, formulation and loading of lead-based initiating compounds. |
| K045 | Spent carbon from treating wastewater containing explosives. |
The industry, production step and waste form tell these K listings apart, not the chemicals in the waste. The rows above are only the nearby listed streams, so also add any characteristic or other listing that fits. One waste can carry more than one federal code.
Which wastes take K047?
| Waste | When it’s K047 |
|---|---|
| Pink or red water from explosives | It is pink or red water from TNT operations |
Which codes sit beside K047?
| Code | What it is |
|---|---|
| K042 | Residues from making the herbicide 2,4,5-T |
| K043 | 2,6-dichlorophenol waste from making the herbicide 2,4-D |
| K044 | Wastewater sludge from making or processing explosives |
| K048 | Float from dissolved-air flotation at a petroleum refinery |
| K049 | Slop-oil emulsion solids from a petroleum refinery |
| K050 | Refinery heat-exchanger cleaning sludge |
| K051 | API oil-water separator sludge from petroleum refining |
| K052 | Leaded tank-bottom residue from a petroleum refinery |
Sources
- 40 CFR 261.32 — Hazardous wastes from specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers
ComplyOnSite