K060 RCRA waste code Toxic lime sludge from a coke oven ammonia still.
- Free, no account
- Based on 40 CFR 261.32 and EPA hazardous-waste rules
- Nothing is stored
Find a federal hazardous waste code
K060, Lime sludge from a coke-plant ammonia still.
K-listed waste
Lime sludge from a coke-plant ammonia still
Industry: Coking.
Is K060 hazardous waste?
Yes. K060 is nonacute K-listed hazardous waste when the waste comes from the named process and matches the named stream. The federal table gives it hazard code (T), toxicity.
A K listing depends on where and how the waste was made, not on a test result alone. A test may add a characteristic code, but it doesn't remove the listing.
On a required hazardous waste manifest, put K060 in Item 13. Check the VSQG exemptions and empty-container rules too.
What does K060 cover?
Lime sludge from the ammonia still at a coking operation. The 261.4(a)(10) exclusion applies only if the sludge is recycled to coke ovens or tar recovery, or mixed with coal tar, and is not land disposed before recycling.
- Hazard code
- (T), toxicity
- Industry
- Coking
- Rule
- 40 CFR 261.32
Is lime sludge from a coke-plant ammonia still always K060?
| Code | When it fits |
|---|---|
| K060 | Ammonia still lime sludge from coking operations. |
| K087 | Decanter tank tar sludge from coking operations. |
| K145 | Residues from naphthalene collection and recovery operations from the recovery of coke by-products produced from coal. |
The industry, production step and waste form tell these K listings apart, not the chemicals in the waste. The rows above are only the nearby listed streams, so also add any characteristic or other listing that fits. One waste can carry more than one federal code.
Which wastes take K060?
| Waste | When it’s K060 |
|---|---|
| Ammonia still lime sludge from coking | It is ammonia still lime sludge from coking operations |
Which codes sit beside K060?
| Code | What it is |
|---|---|
| K049 | Slop-oil emulsion solids from a petroleum refinery |
| K050 | Refinery heat-exchanger cleaning sludge |
| K051 | API oil-water separator sludge from petroleum refining |
| K052 | Leaded tank-bottom residue from a petroleum refinery |
| K061 | Electric-furnace dust or sludge from primary steelmaking |
| K062 | Spent acid pickling liquor from iron or steel finishing |
| K069 | Air-pollution-control dust or sludge from secondary lead smelting |
| K071 | Brine-purification mud from mercury-cell chlorine production |
Sources
- 40 CFR 261.32 — Hazardous wastes from specific sources
- 40 CFR 261.3 — Definition of hazardous waste
- 40 CFR 261.4 — Exclusions
- 40 CFR 260.10 — Definitions
- 40 CFR 262.14 — Conditions for exemption for a very small quantity generator
- 40 CFR 262.20 — General requirements
- Hazardous Waste Manifest Instructions
- 40 CFR 261.7 — Residues of hazardous waste in empty containers