M100 waste code Queensland Old transformer & capacitor oils, and fire-retardant chemicals.
- Free, no account
- Environmental Protection Regulation 2019 and Queensland guidance
- Nothing is stored
Find an Australian waste code
M100, PCB, PCN, PCT or PBB material.
Queensland
PCB, PCN, PCT or PBB material
Queensland M100: PCB, PCN and PCT are polychlorinated biphenyls, naphthalenes and terphenyls; PBB is polybrominated biphenyl.
Is Queensland M100 hazardous waste?
Not from the code alone. M100 is a Schedule 11 trackable-waste description. Tracking applies while the commercial or industrial waste stays regulated under section 42. Check the Schedule 9 exclusions and the section 42(4) test-out route before treating a movement as trackable. This code has no precedence mark when several descriptions fit.
For a tracked load, enter M100 as the waste code on the Queensland waste transport certificate. The generator completes Part 1, the transporter Part 2 and the receiver Part 3. Lodge it through an approved online, bulk-upload or numbered-paper route. The Queensland exclusions still apply.
What does Queensland M100 cover?
Material containing PBB, PCB, PCN or PCT compounds. It covers contamination as well as articles or substances that contain one of these compound groups.
- Official wording
- material containing polychlorinated biphenyls (PCBs), polychlorinated napthalenes (PCNs), polychlorinated terphenyls (PCTs) or polybrominated biphenyls (PBBs)
- Rule or list
- Environmental Protection Regulation 2019
Is PCB, PCN, PCT or PBB material Queensland M100?
| Code | When it fits |
|---|---|
| M100 | The waste contains, or is contaminated with, a listed PCB, PCN, PCT or PBB compound. |
An asterisk in Queensland's tracking list marks which description wins when several fit. It is not an EWC hazardous-waste marker. A resource leaves the waste regime only when it meets its end-of-waste code or approval conditions.
Which wastes take Queensland M100?
| Waste | When it’s M100 |
|---|---|
| PCB-contaminated waste | Analysis confirms PCB contamination on this list. |
| PCN-containing waste | Analysis confirms PCN, under the combined PCB, PCN, PCT and PBB entry. |
| PCT-containing waste | Analysis confirms PCT, under the combined PCB, PCN, PCT and PBB entry. |
| PBB-containing waste | Analysis confirms PBB, under the combined PCB, PCN, PCT and PBB entry. |
ComplyOnSite