Texas waste codes for process wastewater Mostly inorganic water from plant operations.
- Free, no account
- Based on TCEQ RG-022 and 30 TAC Chapter 335
- Nothing is stored
Find a Texas waste code
Process wastewater: 1 code.
Process wastewater
Code choices and management conditions.
Scope and quantity exemptions.
Inorganic liquids
Water-based liquid, low toxic organics
The mainly inorganic aqueous waste has low toxic-organic content.
When to use 102
Which form fits process wastewater?
| Form | When it fits |
|---|---|
| 102 | Mainly inorganic aqueous waste with low toxic-organic content. |
When is process wastewater excluded at discharge?
The 261.4(a)(1) exclusion covers domestic sewage and mixtures that pass through a sewer to a publicly owned treatment works. Discharge restrictions still apply.
The 261.4(a)(2) exclusion covers a permitted Clean Water Act industrial point-source discharge, but only at the point of actual discharge. It doesn't cover collected or stored wastewater or treatment sludge. A tanker load isn't an exempt discharge.
Which form fits collected process wastewater?
Record the dissolved solids, solvents, metals, pH and reactive constituents.
Pick from the inorganic liquid forms or organic liquid forms for the collected liquid. Treatment sludge needs a sludge or solid form.