Texas form code 505 Raw sludge from metal plating, cyanide free.
- Free, no account
- Based on Texas Appendix 3 and TCEQ RG-022
- Nothing is stored
Find a Texas waste code
505, Untreated plating sludge, no cyanides.
Inorganic sludges
Untreated plating sludge, no cyanides
Pumpable untreated plating sludge without cyanides.
Where does Texas form code 505 go in the Texas waste code?
In characters 5–7. The 8-character code is a 4-character stream sequence, the 3-digit form 505 and a final class character. Form 505 puts the stream in the inorganic sludges category.
The form doesn't give a hazard status. The stream's makeup, source and properties decide the class character.
For a hazardous or Class 1 shipment that needs a Uniform Hazardous Waste Manifest, enter the full Texas code in Item 13, across 2 blocks on paper. Add any EPA waste codes alongside it. The 3 form digits alone are not enough.
The generator sets the class from exclusions, federal hazardous-waste listings and characteristics, then Texas industrial-waste criteria. H means hazardous. 1, 2 and 3 are the nonhazardous industrial classes. Testing or process knowledge supports that call, and picking a form doesn't set the class.
What does Texas form code 505 cover?
This form covers mostly inorganic, pumpable sludge from a plating operation, before treatment and with no cyanides. It must be untreated, from plating and free of cyanide.
- Category
- inorganic sludges
- Official wording
- Appendix 3, form 505
- Coding guidance
- RG-022, Chapter 5 and Appendix F
Is untreated plating sludge without cyanide Texas form code 505?
| Code | When it fits |
|---|---|
| 505 | The waste is pumpable untreated plating sludge with no cyanides. |
| 506 | The untreated plating sludge contains cyanides. |
| 507 | The cyanide sludge is not untreated plating sludge. |
Untreated describes the plating sludge, not the whole wastewater system. Keep evidence that cyanides are absent.
Which wastes take Texas form code 505?
| Waste | When it’s 505 |
|---|---|
| Plating sludge without cyanide | The untreated plating sludge contains no cyanide. |
Which codes sit beside Texas form code 505?
| Code | What it is |
|---|---|
| 501 | Lime sludge without metals |
| 502 | Metal-bearing lime or metal-hydroxide sludge |
| 503 | Wastewater sludge with toxic organics |
| 504 | Other wastewater-treatment sludge |
| 508 | Sludge with reactive sulfides |
| 509 | Sludge with other reactives |
| 510 | Degreasing sludge, metal scale or filings |
| 511 | Air-pollution-control sludge |
ComplyOnSite