G110 waste code WA Spent thinners & degreasers with no chlorine or other halogens.
- Free, no account
- WA Controlled Waste Regulations and DWER category guidance
- Nothing is stored
Find an Australian waste code
G110, Non-halogenated organic solvents.
Western Australia
Non-halogenated organic solvents
Western Australia G110: halogenated solvents belong under G150, rather than this non-halogenated entry.
Is WA G110 hazardous waste?
Not from the code alone. G110 is a WA controlled-waste category. Regulation 3 covers industrial, commercial, medical, laboratory and sewage-treatment waste, but not domestic waste. Waste lawfully accepted at a Class I, II or III landfill is excluded, except for specified items including asbestos, tyres and clinical waste.
For a tracked load, enter G110 in the controlled-waste category field on the DWER tracking form. DWER issues the number. The authorised carrier or driver records collection and transport, and the receiving facility closes the record. Record the holder, amount, containment and destination. Road tracking in WA follows the WA load thresholds and exclusions.
What does WA G110 cover?
Organic solvents that aren't halogenated fall here. That separates G110 from halogenated solvents under G150. Process residues from producing or using solvents may fit G160 instead.
- Official wording
- Controlled waste category list
- Source edition
- May 2018
- Rule or list
- Controlled waste category list
Is non-halogenated solvent WA G110 or G150?
| Code | When it fits |
|---|---|
| G110 | The waste is an organic solvent and isn't halogenated. |
| G150 | The organic solvent is halogenated. |
Landfill acceptance depends on the landfill criteria, not on how the waste looks. A category number and a dangerous goods class answer different questions.
Which wastes take WA G110?
| Waste | When it’s G110 |
|---|---|
| Spent solvents | The spent solvent is non-halogenated. |
| Non-halogenated solvents | The spent solvent is non-halogenated. |
Which codes sit beside WA G110?
| Code | What it is |
|---|---|
| F100 | Water-based paint, ink and dye process waste |
| F110 | Water-based resin and adhesive process waste |
| F120 | Solvent-based paint, ink and dye waste |
| F130 | Solvent-based resin and adhesive waste |
| G100 | Ethers and easily ignited hydrocarbons |
| G130 | Perchloroethylene solvent waste |
| G160 | Other organic-solvent process waste |
| H100 | Biocide and crop-treatment chemical waste |