Texas form code 297 Nonhazardous oil-type liquid with a light PCB load.
- Free, no account
- Based on Texas Appendix 3 and TCEQ RG-022
- Nothing is stored
Find a Texas waste code
297, PCB liquids, 50 to under 500 ppm.
Organic liquids
PCB liquids, 50 to under 500 ppm
Nonhazardous liquid with 50 ppm to under 500 ppm PCBs.
Where does Texas form code 297 go in the Texas waste code?
In characters 5–7. The 8-character code is a 4-character stream sequence, then the 3-digit form 297, then a class character. Form 297 describes a stream in the organic liquids category.
This form needs nonhazardous waste. Industrial waste with PCBs at 50 ppm or more is Class 1 when it is not RCRA hazardous, and the PCB form doesn't make that call.
For a hazardous or Class 1 shipment on a Uniform Hazardous Waste Manifest, enter the full Texas code in Item 13, across 2 blocks on paper. Put any EPA waste codes beside it. The 3 form digits alone are not enough.
The generator sets the class from exclusions, federal hazardous-waste listings and characteristics, then Texas industrial-waste criteria. H means hazardous, and 1, 2 and 3 are nonhazardous industrial classes. Process knowledge or testing backs the decision. Picking a form doesn't set the class.
What does Texas form code 297 cover?
A mainly organic, nonhazardous liquid with PCBs at 50 ppm or more but under 500 ppm. It needs both a liquid matrix and that concentration band. Solid, soil, equipment and sludge matrices have their own forms.
- Category
- organic liquids
- Official wording
- Appendix 3, form 297
- Coding guidance
- RG-022, Chapter 5 and Appendix F
Is nonhazardous PCB liquid Texas form code 297 or 298?
| Code | When it fits |
|---|---|
| 297 | The nonhazardous organic liquid holds PCBs at 50 to under 500 ppm. |
| 298 | The nonhazardous organic liquid holds PCBs at 500 ppm or more. |
| 394 | The nonhazardous inorganic solid holds PCBs at 50 to under 500 ppm. |
A hazardous stream needs another best-fitting form, and a PCB level alone doesn't make a waste nonhazardous.
Which wastes take Texas form code 297?
| Waste | When it’s 297 |
|---|---|
| PCB waste | Nonhazardous organic liquid in the lower PCB band. |
| PCB-contaminated liquid | Nonhazardous organic liquid in the lower PCB band. |
ComplyOnSite