Texas form code 405 Solid organic material that can react dangerously.
- Free, no account
- Based on Texas Appendix 3 and TCEQ RG-022
- Nothing is stored
Find a Texas waste code
405, Reactive organic solids.
Organic solids
Reactive organic solids
Non-pumpable organic solid that is reactive.
Where does Texas form code 405 go in the Texas waste code?
In characters 5–7. The 8-character code is a 4-character stream sequence, the 3-digit form 405 and a final class character. Form 405 puts the stream in the organic solids category.
The form doesn't give a hazard status. The stream's makeup, source and properties decide the class character.
For a hazardous or Class 1 shipment that needs a Uniform Hazardous Waste Manifest, enter the full Texas code in Item 13, across 2 blocks on paper. Add any EPA waste codes alongside it. The 3 form digits alone are not enough.
The generator sets the class from exclusions, federal hazardous-waste listings and characteristics, then Texas industrial-waste criteria. H means hazardous. 1, 2 and 3 are the nonhazardous industrial classes. Testing or process knowledge supports that call, and picking a form doesn't set the class.
What does Texas form code 405 cover?
This form covers mostly organic reactive waste that is a solid and won't pump. The reactive basis and the physical form must both be shown.
- Category
- organic solids
- Official wording
- Appendix 3, form 405
- Coding guidance
- RG-022, Chapter 5 and Appendix F
Is reactive organic solid waste Texas form code 405?
| Code | When it fits |
|---|---|
| 405 | The waste is reactive organic waste that is solid and won't pump. |
| 212 | The reactive or polymerizable organic waste is a highly fluid liquid. |
| 605 | The reactive or polymerizable organic waste is a pumpable sludge. |
A solid is not reactive just because it came from a reactive liquid. Name the reactive constituent or property that the waste record supports.
Which wastes take Texas form code 405?
| Waste | When it’s 405 |
|---|---|
| Reactive organic solids | The organic solid that won't pump is reactive. |