Skip to content

Texas waste code finder

Texas form code 494 Organic solid with 50 to under 500 ppm PCBs.

  • Free, no account
  • Based on Texas Appendix 3 and TCEQ RG-022
  • Nothing is stored

Find a Texas waste code

494, PCB organic solids, 50 to under 500 ppm.

  • Organic solids

    PCB organic solids, 50 to under 500 ppm

Organic solid with 50 ppm to under 500 ppm PCBs.

Organic solid in the lower PCB band, from 50 ppm to under 500 ppm. Soil and equipment have separate forms.

Where does Texas form code 494 go in the Texas waste code?

In characters 5–7. The 8-character code is a 4-character stream sequence, the 3-digit form 494 and a final class character. Form 494 puts the stream in the organic solids category.

These PCB bands don't replace the hazardous-waste determination. If the waste isn't RCRA hazardous, industrial waste with at least 50 ppm PCBs is Class 1.

For a hazardous or Class 1 shipment that needs a Uniform Hazardous Waste Manifest, enter the full Texas code in Item 13, across 2 blocks on paper. Add any EPA waste codes alongside it. The 3 form digits alone are not enough.

The generator sets the class from exclusions, federal hazardous-waste listings and characteristics, then Texas industrial-waste criteria. H means hazardous. 1, 2 and 3 are the nonhazardous industrial classes. Testing or process knowledge supports that call, and picking a form doesn't set the class.

What does Texas form code 494 cover?

Mostly organic solid waste that won't pump, with PCBs at 50 ppm or more but under 500 ppm. Soil and electrical equipment have their own forms, and the wording doesn't expressly keep them out of this general solid form.

Category
organic solids
Official wording
Appendix 3, form 494

Is a PCB-contaminated organic solid Texas form code 494?

CodeWhen it fits
494The organic solid has PCBs at 50 to under 500 ppm.
495The organic solid has PCBs at 500 ppm or more.
496The organic electrical equipment has PCBs at 50 to under 500 ppm.
498The organic soil has PCBs at 50 to under 500 ppm.

Record the material, its organic makeup and the PCB concentration. The form digits don't encode the class. For nonhazardous industrial waste, PCBs at 50 ppm or more make it Class 1.

Which codes sit beside Texas form code 494?

CodeWhat it is
488Wood debris
489Petroleum-contaminated solids
490Organic sandblasting waste
491Dewatered biological-treatment sludge
492Dewatered sewage/untreated biological sludge
493Catalyst (reaction aid), organic solid
497PCB organic devices, 500 ppm or more
499PCB organic soil, 500 ppm or more