Texas form code 498 Organic soil with 50 to under 500 ppm PCBs.
- Free, no account
- Based on Texas Appendix 3 and TCEQ RG-022
- Nothing is stored
Find a Texas waste code
498, PCB organic soil, 50 to under 500 ppm.
Organic solids
PCB organic soil, 50 to under 500 ppm
Organic soil with 50 ppm to under 500 ppm PCBs.
Where does Texas form code 498 go in the Texas waste code?
In characters 5–7. The 8-character code is a 4-character stream sequence, the 3-digit form 498 and a final class character. Form 498 puts the stream in the organic solids category.
These PCB bands don't replace the hazardous-waste determination. If the waste isn't RCRA hazardous, industrial waste with at least 50 ppm PCBs is Class 1.
For a hazardous or Class 1 shipment that needs a Uniform Hazardous Waste Manifest, enter the full Texas code in Item 13, across 2 blocks on paper. Add any EPA waste codes alongside it. The 3 form digits alone are not enough.
The generator sets the class from exclusions, federal hazardous-waste listings and characteristics, then Texas industrial-waste criteria. H means hazardous. 1, 2 and 3 are the nonhazardous industrial classes. Testing or process knowledge supports that call, and picking a form doesn't set the class.
What does Texas form code 498 cover?
This form covers soil that is mostly organic and holds PCBs at 50 ppm or more but under 500 ppm. The soil matrix separates it from other organic solids and electrical equipment in the same band.
- Category
- organic solids
- Official wording
- Appendix 3, form 498
- Coding guidance
- RG-022, Chapter 5 and Appendix F
Is PCB-contaminated soil in the lower band Texas form code 498?
| Code | When it fits |
|---|---|
| 498 | The organic soil has PCBs at 50 to under 500 ppm. |
| 499 | The organic soil has PCBs at 500 ppm or more. |
| 398 | The nonhazardous inorganic soil has PCBs at 50 to under 500 ppm. |
| 494 | The organic solid has PCBs at 50 to under 500 ppm. |
Record the material, its organic makeup and the PCB concentration. The form digits don't encode the class. Nonhazardous industrial waste with PCBs at 50 ppm or more is Class 1.
Which wastes take Texas form code 498?
| Waste | When it’s 498 |
|---|---|
| Contaminated soil | Organic soil in the lower PCB band, subject to the PCB form-selection rules. |
Which codes sit beside Texas form code 498?
| Code | What it is |
|---|---|
| 489 | Petroleum-contaminated solids |
| 490 | Organic sandblasting waste |
| 491 | Dewatered biological-treatment sludge |
| 492 | Dewatered sewage/untreated biological sludge |
| 493 | Catalyst (reaction aid), organic solid |
| 495 | PCB organic solids, 500 ppm or more |
| 496 | PCB organic devices, 50 to under 500 ppm |
| 497 | PCB organic devices, 500 ppm or more |