Skip to content

Australian waste code finder

M100 waste code South Australia Old transformer & capacitor oils, plus fire-retardant biphenyls.

  • Free, no account
  • SA EPA waste-code and tracking tables
  • Nothing is stored

Find an Australian waste code

M100, PCB, PCN, PCT or PBB material.

  • South Australia

    PCB, PCN, PCT or PBB material

South Australia M100: PCB, PCN and PCT are polychlorinated biphenyls, naphthalenes and terphenyls; PBB is polybrominated biphenyl.

Waste substances & articles containing PCB, PCN, PCT or PBB in South Australia. All are halogenated biphenyls.

Is South Australia M100 hazardous waste?

Not from the code alone. The SA EPA operational code list and its table of waste requiring tracking are separate, so a code can be on one and not the other. The description doesn't approve a receiving facility or a disposal method.

M100 is in the SA table for waste requiring tracking, within the state or interstate. Enter it with the SA description on the WasteTracker transport certificate, against a matching consignment authorisation. The consignor, transporter and receiver each complete their own part. The SA tracking exemptions still apply.

What does South Australia M100 cover?

Discarded substances or articles containing PCB, PCN, PCT or PBB go here. Contaminated waste fits too, as well as articles or substances that contain one of those groups.

Is PCB, PCN, PCT or PBB waste South Australia M100?

CodeWhen it fits
M100The waste contains or is contaminated with a listed PCB, PCN, PCT or PBB compound.

Use the SA EPA operational entry for an SA load. The separate interstate Policy description is kept where its wording differs, but it doesn't replace the operational table or settle tracking on its own.

Which wastes take South Australia M100?

WasteWhen it’s M100
PCB-contaminated wasteAnalysis confirms PCB contamination on this list.
PCN-containing wasteAnalysis confirms PCN within the combined PCB, PCN, PCT and PBB entry.
PCT-containing wasteAnalysis confirms PCT within the combined PCB, PCN, PCT and PBB entry.
PBB-containing wasteAnalysis confirms PBB within the combined PCB, PCN, PCT and PBB entry.

Which codes sit beside South Australia M100?

CodeWhat it is
K120Liquid food waste
K130Sewage sludge and residue
K140Tannery waste from leather processing
K190Wool-scouring waste
M150Phenols and phenolic compounds
M160Other organohalogen compounds
M170Polychlorinated dibenzofurans
M180Polychlorinated dioxins