Skip to content

Australian waste code finder

A100 waste code Queensland Plating, anodising & etching waste from metal & plastic finishing.

  • Free, no account
  • Environmental Protection Regulation 2019 and Queensland guidance
  • Nothing is stored

Find an Australian waste code

A100, Metal and plastic surface-treatment waste.

  • Queensland

    Metal and plastic surface-treatment waste

Queensland A100: surface treatment is the source; compare heat-treatment cyanide waste under A110.

Waste from finishing metals or plastics, such as plating, anodising & etching baths. Cyanide waste from heat treatment is A110.

Is Queensland A100 hazardous waste?

Not from the code alone. A100 is a Schedule 11 trackable-waste description. Tracking applies while the commercial or industrial waste is regulated under section 42. Check the Schedule 9 exclusions and the section 42(4) test-out route before you decide whether a movement is trackable. This code has no precedence mark when several descriptions fit.

For a tracked load, enter A100 as the waste code on the Queensland waste transport certificate. The generator supplies Part 1, the transporter Part 2 and the receiver Part 3. Lodge it by the approved online, bulk-upload or numbered-paper route. The Queensland exclusions still apply.

What does Queensland A100 cover?

Waste from operations that treat metal or plastic surfaces. The category is set by the process that made the waste, not by a named metal, plastic or treatment chemical.

Official wording
waste from surface treatment of metals or plastics

Is surface-treatment waste Queensland A100 or A110?

CodeWhen it fits
A100The waste arose directly from surface treatment of metal or plastic.
A110The waste comes from cyanide heat treatment or tempering, not metal or plastic surface treatment.

In Queensland's tracking list an asterisk sets precedence when several descriptions fit. It is not an EWC hazardous-waste marker. A resource leaves the waste regime only once it meets its end-of-waste code or approval conditions.

Which wastes take Queensland A100?

WasteWhen it’s A100
Surface-treatment wasteThe waste comes from metal or plastic surface treatment.

Which codes sit beside Queensland A100?

CodeWhat it is
A130Inorganic cyanides
B100Acidic liquids and solid acids
C100Alkaline liquids and solid alkalis
D100Metal carbonyl compounds
D110Inorganic fluorine compounds
D120Mercury and mercury compounds
D130Arsenic and arsenic compounds
D140Chromium compounds