ACT controlled waste codes Canberra's list of 72 waste types, from acids to solvents.
- Free, no account
- Official state lists and movement guidance
- Nothing is stored
Find an Australian waste code
Pick a waste or type one, and each state’s codes for it show here.
Which waste code list applies in the ACT?
The ACT producer guide publishes a 72-code appendix. It is an older administrative list and has no dedicated PFAS entry. It sets the listed codes, but doesn't prove that no newer code can be accepted.
How do waste classification and tracking differ in the ACT?
Keep the interstate controlled-waste procedure apart from ACT local landfill approvals and clinical-waste licensing. For waste entering the ACT under the NEPM route, prepare the destination approval and transport certificate before dispatch. For ACT interstate movement, a waste is controlled only when it is in NEPM Schedule A List 1 and has a List 2 hazardous characteristic. The interstate division doesn't apply to movement wholly within the ACT, emergencies, approved analysis or research, pipelines, or residual containers returned for refilling with the same substance. Intraterritory regulated-waste duties are separate.
Which ACT materials have their own route?
Material-specific routes for the ACT are on the Waste acids, Alkaline waste, Asbestos waste, Contaminated drums and containers, Contaminated soil, Paint waste, Spent solvents and Used oil pages.
Applies to Waste acids, Alkaline waste. Larger or commercial quantities need a private service provider.
Applies to Consolidated household chemicals, Paint waste, Pesticide and biocide waste, Photographic chemicals, Spent solvents, Varnish and lacquer waste. Private service providers take larger and commercial quantities.
Consolidated household chemicals. You can drop off small quantities of unwanted household chemicals free at Mugga Lane or Mitchell.
Industrial wastewater. The ACT has no liquid-waste disposal facility and limited treatment for commercial volumes, so most commercial liquid waste must go interstate. It must not enter a drain, sewer or stormwater system, whatever the quantity.
Pesticide and biocide waste. You can use the free household chemical drop-off at Mugga Lane or Mitchell for small quantities of unwanted household pesticides and garden chemicals.
Photographic chemicals. You can use the free household chemical drop-off at Mugga Lane or Mitchell for small quantities of unwanted household photographic chemicals.
Varnish and lacquer waste. You can use the free household chemical drop-off at Mugga Lane or Mitchell for small quantities of unwanted household varnish or stain.
What record do I need after classifying waste in the ACT?
For an ACT interstate controlled-waste movement, get destination approval and prepare the waste transport certificate. Local regulated-waste approvals are a separate check.
Australian Capital Territory’s 72 waste codes
Each code links to its page.
Australian Capital Territory waste code list 72 codes
- A100 Metal and plastic surface-treatment waste
- A110 Cyanide heat-treatment waste
- A130 Inorganic cyanides
- B100 Acidic liquids and solid acids
- C100 Alkaline liquids and solid alkalis
- D100 Metal carbonyl compounds
- D110 Inorganic fluorine compounds
- D120 Mercury and mercury compounds
- D130 Arsenic and arsenic compounds
- D140 Chromium compounds
- D150 Cadmium and cadmium compounds
- D160 Beryllium and beryllium compounds
- D170 Antimony and antimony compounds
- D180 Thallium and thallium compounds
- D190 Copper compounds
- D200 Cobalt compounds
- D210 Nickel compounds
- D220 Lead and lead compounds
- D230 Zinc compounds
- D240 Selenium and selenium compounds
- D250 Tellurium and tellurium compounds
- D270 Vanadium compounds
- D290 Barium compounds
- D300 Non-toxic salts
- D310 Boron compounds
- D330 Inorganic sulphides
- D340 Perchlorates
- D350 Chlorates
- D360 Phosphorus compounds
- E100 Peroxide waste excluding hydrogen peroxide
- E120 Explosive waste
- F100 Paint, ink and dye waste
- F110 Resin, latex and adhesive waste
- G100 Ethers (oxygen-linked organic compounds)
- G110 Non-halogenated organic solvents
- G150 Halogenated organic solvents
- G160 Other organic-solvent process waste
- H100 Biocide and crop-treatment chemical waste
- H110 Organic phosphorus compounds
- H170 Wood-preservative chemical waste
- J100 Waste mineral oil
- J120 Oil-and-water mixtures
- J160 Tarry refining and treatment residue
- K100 Animal-processing effluent and residue
- K110 Grease-trap waste
- K140 Tannery waste from leather processing
- K190 Wool-scouring waste
- M100 PCB, PCN, PCT or PBB material
- M150 Phenols and phenolic compounds
- M160 Other organohalogen compounds
- M170 Polychlorinated dibenzofurans
- M180 Polychlorinated dioxins
- M210 Organic cyanides
- M220 Isocyanates used in polyurethane products
- M230 Triethylamine foundry-sand catalyst
- M250 Surfactants and detergents
- M260 Strong-smelling organic chemicals
- N100 Contaminated containers and drums
- N120 Contaminated soil
- N140 Fire debris and washwater
- N150 Fly ash
- N160 Fixed, solidified or encapsulated waste
- N190 Filter cake (solids left after filtration)
- N205 Industrial waste-treatment residue
- N220 Asbestos waste
- N230 Asbestos-like ceramic fibres
- R100 Clinical and related waste
- R120 Discarded medicines and pharmaceuticals
- R140 Pharmaceutical-production waste
- T100 Research, laboratory and teaching chemicals
- T120 Photographic chemical waste
- T140 Used tyres
Sources
- Clinical and hazardous waste
- Environment Protection Regulation 2005, Part 7 Division 7.2
- Guide to using a waste transport certificate
- Environmental Standards: Assessment and Classification of Liquid and Non-liquid Wastes
- Environment Protection Regulation 2005
- National Environment Protection (Movement of Controlled Waste between States and Territories) Measure 1998, compilation F2012C00858
- Responsibilities of controlled waste producers in the ACT
ComplyOnSite